AP54.10-P-5410V

Batteries - check fluid level, correct

14.2.12

MODEL 171

Batteries - check fluid level, correct

P54.10-2337-08

1 Cover

1a Locking

3 Plug

G1 Battery

2 Tensioning clamp

2a Nut

Remove/Install

Danger!

Risk of explosion caused by escaping oxyhydrogen gas. Risk of injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte (contains diluted sulfuric acid) or metal spatter due to short circuit. Risk of burn injuries caused by short circuit. Risk of poisoning caused by swallowing battery electrolyte (contains diluted sulfuric acid) or absorption of lead over the skin or orifices

No fire, sparks, open flames or smoking.

Wear acid-resistant gloves and clothing and safety glasses with side guards.

Do not place any conductive objects on the battery and avoid any short circuit from battery positive to ground.

Only fill liquid battery electrolyte (diluted sulfuric acid) into suitable and appropriately marked containers.

AS54.10-Z-0001-01A

Notes on battery

AH54.10-P-0001-01A

1

Open engine hood and raise to
vertical position

Opening engine hood, moving to upright position and closing

AR88.40-P-1000V

2

Open locks (1a) and remove cover (1)

3

Unscrew nut (2a) and remove
retaining clip (2)

4

Unscrew plugs (3) of battery cells from
the battery (G1)

Check

5

Check fluid level in the cells of the
battery (G1)

In each cell the fluid must reach the web let into the filler opening (arrow).
Only use distilled water for refilling.

6

Install in the reverse order