Inspect radiator for external soiling, clean according to condition

Type ap · emne 20.20 · version 0102 · 2009-09-29

Gælder for: ENGINES 612.966 in MODEL 461 ENGINES 642 in MODEL 461

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 1 Motor › 20 Motorkøling › 20.20 Køler, kølerslanger — Serie 461

EinPAS 15 Motor › 15.25 Motorkølesystem › 15.25.31 Motorkøler — Serie 461

Gælder også for motorer/gearkasser: 612 966, 642 ***

AP20.20-P-2052GM

Inspect radiator for external soiling, clean according to condition

24.9.09

ENGINES 612.966 in MODEL 461

ENGINES 642 in MODEL 461

Inspect radiator for external soiling, clean according to condition

P20.20-2312-11

1 Radiator

Removing

1

Open engine hood

Opening engine hood, moving to upright position and closing

AR88.40-P-1000GG

Checking

2

Inspect radiator (1) for external soiling

The fins must not be clogged with dirt.

If required, clean the radiator (1) against a separate computation.

Cleaning

3

Remove radiator (1)

Only perform if radiator (1) to be cleaned.

Remove/install radiator

Engine 612

AR20.20-P-3865GT

Remove/install radiator

Engine 642

AR20.20-P-3865GY

4.1

Remove any minor contamination in the radiator (1) using compressed air or by spraying with water

Guide water jet at an adequate distance to the lamella otherwise the radiator (1) will be damaged.

4.2

Spray out severe contamination of the radiator (1) using high pressure cleaner

Guide high-pressure jet at an adequate distance to the lamella otherwise the radiator (1) will be damaged.

Install

5

Install radiator (1)

Remove/install radiator

Engine 612

AR20.20-P-3865GT

Remove/install radiator

Engine 642

AR20.20-P-3865GY

6

Close engine hood

Opening engine hood, moving to upright position and closing

AR88.40-P-1000GG