ad8370d4000b

Auxiliary heater (AHE) diagnosis fault memory

Type ad · emne 83.70 · version 0101 · 2003-06-13

Gælder for: MODEL 901.###, 902.###, 903.###, 904.### ## up to 753730 up to 31.10.97 with CODE (H11) Warm air auxiliary heater Heater unit designation B3L-C, Heater unit designation D3L-C

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 3 Karrosseri › 83 Klimatisering › 83.70 Parkeringsvarmesystem, ekstra varmesystem, ekstra varmeapparat — Serie 901 · Serie 902 · Serie 903 · Serie 904

AD83.70-D-4000B

Auxiliary heater (AHE) diagnosis fault memory

27.6.97

MODEL 901.###, 902.###, 903.###, 904.### ## up to 753730 up to 31.10.97 with CODE (H11) Warm air auxiliary heater
Heater unit designation B3L-C,
Heater unit designation D3L-C

Danger!

Risk of explosion due to fuel vapors, risk of poisoning from inhaling combustion gases and risk of injury from burns during or after heater operation.

Do not put stationary heater/auxiliary heater or engine with heater booster into operation in confined spaces or while refuelling. Allow heater unit to cool down after operation and wear safety gloves.

AS83.70-Z-0002-01A

Auxiliary heater (AHE) diagnosis, previous knowledge

AD83.70-D-2000E

I

Battery voltage > 9.5 Volts

II

Auxiliary heater complete (all connectors connected)

III

Connect Hand-Held Tester (HHT)

AD00.00-D-2000-03A

IV

Ignition and auxiliary heater switched on

Cables, plugs and connectors are also taken into account on the tests with the HHT and, if a fault is displayed, may have to be checked again separately in accordance with the relevant electric wiring diagram for open-circuit, good contact and correct connection.

Fault code

Fault text (HHT)

Possible cause/Remedy

Overvoltage shut-off

Check regulating voltage

Undervoltage shut-off

Check fuse F9. Check battery and regulating voltage.

Check electric cables (voltage drop)

Overheating or metering pump –//–

Check inlet and outlet of hot air pipe for obstruction and eliminate obstruction if necessary

Check electric cables and connections on metering pump.

Check overheating switch

Overheating of flame sensor

Check flame sensor and replace if necessary

Glow plug –//–

Check glow plug and replace if necessary.

Check electric cables and connections

If in order, replace printed-circuit board

Current regulator printed-circuit board

–//–

Check electric cables. If in order, replace printed-circuit board

Diagnosis output

Check electric cables

Blower motor or speed regulator defective

Check connections to blower motor. Check motor and replace blower if necessary. If in order, replace printed-circuit board.

Speed specified value signal

Check electric cables and connection. If in order, replace printed-circuit board

Metering pump

Check metering pump and replace if necessary. Check electric cables and connections

Too many attempts at starting

Control module lock-out due to failure to start 5 times in succession (refer to code )

Does not start

Check fuel supply. Check glow plug and replace if necessary. Check flame sensor

Flame goes out during operation

Check fuel supply, quantity of fuel and blower speed.

If combustion is in order, check flame sensor.

Temperature sensor

–//–

Check connector to temperature sensor.

Check temperature sensor on printed-circuit board and replace printed-circuit board if necessary.

Heater timer

–//–

Check connections on heater timer and replace heater timer if necessary.

Flame sensor

–//–

Check connector to flame sensor. Check flame sensor and replace if necessary

External interference voltages

Eliminate interference voltages

Control module defective

Replace control module

Henviste dokumenter