AD83.40-S-4001B | Tempmatic (TM) diagnosis fault memory | 22.10.98 |
MODEL 638.094 /194 /294 with CODE (H06) Air conditioning
Connection and use of test equipment | |||
Connect Hand-Held Tester (HHT) and read out fault memory | |||
Tempmatic (TM) - Diagnosis - background knowledge | |||
a | Battery voltage 11 - 14 V | ||
b | All plug connectors connected | ||
c | All fuses in order | ||
d | In the event of a fault being indicated, carry out the respective test procedure in the electrical test program | ||
Fault memory | |||
Fault code | Fault text | Possible cause/note | Remedy |
| Evaporator temperature sensor | Short-circuit to ground Short-circuit to plus or fault | |
| Temperature sensor, Air discharge | Short-circuit to ground Short-circuit to plus or fault | |
| Pressure sensor, refrigerant, air conditioning regulation Short-circuit to ground Short-circuit to plus or fault | Short-circuit to ground Short-circuit to plus or fault | |
| CAN databus fault, Communication | ||
| Fault, auxiliary heater | Short-circuit to ground Short-circuit to plus or fault | |
| Fault, compressor clutch air conditioning system | Short-circuit to ground Short-circuit to plus or fault | |
| Fault, heater fan stage 1 | Short-circuit to ground Short-circuit to plus or fault | |
| Fault, circulating valve | Short-circuit to ground Short-circuit to plus or fault | |
| Fault, auxiliary pump, heating water | Short-circuit to ground Short-circuit to plus or fault | |
| Fault, cycle valve, air conditioning system | Short-circuit to ground Short-circuit to plus or fault | |
| Fault, fan engine cooling (A34) Engine 111.950/980 from 1.2.00 or 611.980 with air conditioning | Short-circuit to ground Short-circuit to plus or fault | |
| Fault, engine cooler module (A80) Model 638.294 with Engine 104.900 with air conditioning | Short-circuit to ground Short-circuit to plus or fault | |
| Fault, max. heater mode not in order | Specified conditions not satisfied | |
| Fault, max. cooling mode not in order | Specified conditions not satisfied | Engine speed < 600 RPM Refrigerant pressure > 28 bar Refrigerant pressure < 2 bar Evaporator temperature < 2 °C Cooling water temperature > 115 °C |
| Fault, band tests | Starting conditions not satisfied: Water temperature >70°C or resistance of the flame monitor resistance >1240Ω Cables Heater fan Auxiliary heater flame monitor Refrigerant temperature switch B94 Auxiliary pump, heating water Flame formation in heater Air bubbles in water circuit |
Henviste dokumenter
- ad0000s1000az Tilslutning og anvendelse af kontrolmidler
- ad0000s200003a Tilslutning af håndtester (HHT), aflæsning af fejlhukommelse
- ad8325s600102a
- ad8340s2001a
- ad8340s600103a
- ad8340s600104a
- ad8340s600105a
- ad8340s600106a
- ad8340s600107a
- ad8340s600108a
- ad8340s600109a
- ad8340s600110a
- ad8340s600110b
- ad8340s600111a
- ad8340s600111b
- ad8370s600006b
- ad8370s600009b
- ad8370s600012b
- ad8370s600013b
- ad8370s600074a