AD83.40-S-6001-03A | Air circulation valve, testing electrical system TM |
| Scope of test | Measuring instrument/ Test connection | Operation/Requirement | Specified value | Possible cause/Remedy | ||
1.0 | Air circulation valve (Y95) Short-circuit to positive |
| A20.2 |
11 | Connector 2 disconnected from A20 Air circulation valve disconnected Ignition: ON |
< 1 V | Cables 1.1 |
1.1 | Air circulation valve (Y95) Short-circuit to ground |
| A20.2 |
11 | Ignition: OFF Connector 2 disconnected from A20 Air circulation valve disconnected |
> 20 Ω | Cables 1.2 |
1.2 | Air circulation valve (Y95) Ground connection |
| Y95.1 |
2 | Air circulation valve disconnected |
< 1 Ω | Cables Connection to W8.1 1.3 |
1.3 | Air circulation valve (Y95) Internal resistance |
| A20.2 |
11 | Ignition: OFF Connector 2 disconnected from A20 |
25 - 35 Ω | Air circulation valve Y95 |