Scope of test

Measuring instrument/

Test connection

Operation/Requirement

Specified value

Possible cause/Remedy

1.0

Purge control valve (Y58/2) or (Y58/3)

Actuation

10

(1.10)

N3/11

N3/12

25

(1.25)

Engine at operating temperature and idling

Purge control valve (Y58/2) and (Y58/3) must cycle noticeably after approx. 1 min., refer to

GF07.61-P-0001-01U

For signal refer to

AD07.61-P-2000-03B

1.1

AD07.61-P-6000-30D

Engine control module (ME-SFI) (N3/11) or (N3/12)

1.1

Current consumption Y58/2 or Y58/3

38

(1.38)

N3/11

N3/12

10

(1.10)

Ignition: ON

0.1–0.3 A

Cable

Y58/2 or Y58/3