ad0761p600030d

Purge control valve vacuum control, testing electrical system of fuel injection system (ME-SFI)

Type ad · emne 07.61 · version 0100 · 2003-06-10

Gælder for: ENGINE 120

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 1 Motor › 07 Blandingstilberedning › 07.61 Benzinindsprøjtnings- og tændingssystem ME

EinPAS 16 Brændstof-/energiforsyning motor › 16.10 Brændstofforsyning › 16.10.1 Grundinformation

Gælder også for motorer/gearkasser: 120 ***

AD07.61-P-6000-30D

Purge control valve vacuum control, testing electrical system of fuel injection system (ME-SFI)

Scope of test

Measuring instrument/

Test connection

Operation/Requirement

Specified value

Possible cause/Remedy

1.0

Purge control valve (Y58/2) or (Y58/3)

Vacuum control

Connect vacuum tester to Y58/2 or Y58/3 connection (A),
refer to

GF07.61-P-0001-01U

Engine at operating temperature and idling.

Increase engine speed slowly up to a maximum of 3000 rpm.

> 50 mbar after approx. 1 minute and pointer fluctuates

Vacuum lines

Y58/2 or Y58/3

Henviste dokumenter