Fault code description for purge control valve, ME

Type ad · emne 07.61 · version 0102 · 2005-08-17

Gælder for: ENGINE 112.910 /911 /920 /921 /922 /940 /941 /942 /944 as of 1.6.00 ENGINE 112.912 /913 /914 /916 /917 /923 /943 /946 /947 /949 /953 /954 /955 /970 /972 /973 /975 ENGINE 113.940 /941 /942 /943 /960 as of 1.6.00 ENGINE 113.948 /961 /963 /964 /965 /966 /967 /968 /969 /971 ENGINE 112.945, 113.962 as of 1.11.00 in MODEL 463 ENGINE 137.970

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 1 Motor › 07 Blandingstilberedning › 07.61 Benzinindsprøjtnings- og tændingssystem ME — Serie 463

EinPAS 16 Brændstof-/energiforsyning motor › 16.10 Brændstofforsyning › 16.10.1 Grundinformation — Serie 463

Gælder også for motorer/gearkasser: 112 910, 112 911, 112 912, 112 913, 112 914, 112 916, 112 917, 112 920, 112 921, 112 922, 112 923, 112 940, 112 941, 112 942, 112 943, 112 944, 112 945, 112 946, 112 947, 112 949, 112 953, 112 954, 112 955, 112 970, 112 972, 112 973, 112 975, 113 940, 113 941, 113 942, 113 943, 113 948, 113 960, 113 961, 113 962, 113 963, 113 964, 113 965, 113 966, 113 967, 113 968, 113 969, 113 971, 137 970

AD07.61-P-4000-19L

Fault code description for purge control valve, ME

Purge control valve, voltage supply

1

Fault code

( Readout on generic scan tool)

P2026 (P0443)

2

Fault storage

Actuation of the engine diagnosis indicator lamp (EURO3/4)

or CHECK ENGINE (MIL) malfunction indicator lamp

after expiry of test duration and fault

following two successive driving cycles with faults

3

Checking frequency

Continuous

4

Checked signal or status

Voltage and current at purge control valve

5

Fault setting conditions

Limit values

Short circuit to ground

Short circuit to +12 V

Open circuit in wiring

Checking duration

Voltage lower than 4 volts

Current higher than 4.2 amps

No voltage on the purge control valve,

Approx. 4 to 8 V on under no load output of the ME control unit

approx. 1 seconds

6

Actuation of the purge control valve is checked for to detect a line discontinuity and short-circuit (to ground or battery voltage). A short circuit to ground and a line discontinuity will be recognized when the output stages are locked, while a short circuit to the battery voltage is recognized when the output stages are conducting.

The output stage is immediately no longer activated when a fault arises.

If the purge control valve does not close (jams), the fault purge system has a gross leak will be stored.