ad0761p400008b

ME-SFI fault code description O2 sensor heater

Type ad · emne 07.61 · version 0100 · 2003-06-06

Gælder for: ENGINE 120

Ikke tilgængelig på “da”; vises på Engelsk.

Placering

Funktionsgruppe 1 Motor › 07 Blandingstilberedning › 07.61 Benzinindsprøjtnings- og tændingssystem ME

EinPAS 15 Motor › 15.45 Motorstyring › 15.45.1 Grundinformation

Gælder også for motorer/gearkasser: 120 ***

AD07.61-P-4000-08B

ME-SFI fault code description O2 sensor heater

1

Fault code

right before TWC

right after TWC

left before TWC

left after TWC

2

Fault memory and actuation of CHECK ENGINE (MIL)

After two consecutive journeys with fault

3

Frequency of testing

Continuous

4

Checked signal or status

Calculated resistance value of sensor heater

5

Lower limit value

Upper limit value

< 4.4 Ω (corresponds to approx. 2.7 A at 12 V)

> 18.4 Ω (corresponds to approx. 0.65 A at 12 V)

6

Test conditions

Sensor heater ON and heating-up time of approx. 220 seconds elapsed