MR (PLD) test of hydraulic system fuel return flow quantity at nozzle holder combinations

Test procedure

Measuring instrument/test connection

Operation/

Preconditions

Specified value

Possible cause/

Remedy

1.0

Test fuel return flow quantity at nozzle holder combinations

Attach testing and measuring equipment to low-pressure fuel circuit

& (AR07.15-G-2000-01BD)

Engine: starting

Idle speed:

Model 405.05

800 rpm

Model 405.10/12/20/22,

Model 437.42/43

720 rpm

Model 437.46

850 rpm

Test period 5 min:

Maximum governed rpm:

2500 rpm

Test period 5 min:

moist with oil

max. only in drips

Fuel or coolant flows out at leak oil drilling or leak oil line

& (AD07.15-G-5001-05B)