ad0715g700107b
MR (PLD) test of hydraulic system fuel return flow quantity at nozzle holder
combinations
Type ad · emne 07.15 · version 0105 · 2012-01-11
Gælder for: ENGINE 900.91 /92, 902.92 /93, 904.92 /95, 906.935 /95, 924.91 /92 /93, 926.96
Ikke tilgængelig på “da”; vises på Engelsk.
Placering
Funktionsgruppe 1 Motor › 07 Blandingstilberedning › 07.15 Dieselindsprøjtningssystem (PLD), motorregulering (MR) — Serie 900 (modeller 91*, 92*) · Serie 902 (modeller 92*, 93*) · Serie 904 (modeller 92*, 95*) · Serie 906 (modeller 935, 95*)
EinPAS 15 Motor › 15.45 Motorstyring › 15.45.1 Grundinformation — Serie 900 (modeller 91*, 92*) · Serie 902 (modeller 92*, 93*) · Serie 904 (modeller 92*, 95*) · Serie 906 (modeller 935, 95*)
Gælder også for motorer/gearkasser: 924 91*, 924 92*, 924 93*, 926 96*
AD07.15-G-7001-07B
| MR (PLD) test of hydraulic system fuel return flow quantity at nozzle holder combinations
|
|
|
| Test procedure
| Measuring instrument/test connection
| Operation/
Preconditions
| Specified value
| Possible cause/
Remedy
|
|
|
|
|
|
|
|
|
|
1.0
| Test fuel return flow quantity at nozzle holder combinations
Attach testing and measuring equipment to low-pressure fuel circuit
& (AR07.15-G-2000-01BD)
|
|
|
| Engine: starting
Idle speed:
Model 405.05
800 rpm
Model 405.10/12/20/22,
Model 437.42/43
720 rpm
Model 437.46
850 rpm
Test period 5 min:
Maximum governed rpm:
2500 rpm
Test period 5 min:
|
moist with oil
max. only in drips
| Fuel or coolant flows out at leak oil drilling or leak oil line
& (AD07.15-G-5001-05B)
|