07.1-010 Function injection system
L. Governor impulse method (RIV)
In order to be able to register the relationship of the injection pump relative to the engine two signals are required:
TDC impulse from the crankshaft
Governor impulse from the injection pump
Both impulses are supplied by pulse generators. In order to obtain a measuring signal the sensor pins must be moved past the pulse generators with a minimum speed (idle speed). A measuring instrument measures the time interval of the two impulses, converting the result into an angular value which is then indicated.
Checking, adjusting start of delivery
(see 07.1-111/112/116/117).
001 Digital tester
015 Test cable
016 Socket
017 RI generator (governor impulse)
021 TDC pulse generator
059 Sensor pin
2 Governor
2i Flyweight with sensor pin