07.1-150 Checking vacuum shut-off for leaks
Job no. of Job Texts and Work Units or Standard Texts and Flat Rates 07-8222 and 8225 |
1st version
A | Partition panel |
c | Remaining users |
e | To brake booster |
1 | Injection pump |
6 | Vacuum unit (stop) |
61b | Choke 0.5 mm orifice diameter |
61c | Valve glow starter switch |
61d | Cam glow starter switch (valve open) |
67 | Vacuum pump |
Glow starter switch | turn to position "2". |
Vacuum tester (019) | connect to suction line "brown" and apply vacuum of 400+50 mbar (max. pressure drop 6 mbar/min). |
Vacuum tester (019) | connect to vacuum unit (6) and apply vacuum of 300+50 mbar (max. pressure drop |
2nd version
Production breakpoint as of July 1987.
A | Partition panel |
c | Remaining users |
e | To brake booster |
1 | Injection pump |
6 | Vacuum unit (stop) |
61c | Valve glow starter switch |
67 | Vacuum pump |
140 | Check valve/main vacuum line |
Glow starter switch | press to position "2". |
Vacuum tester (019) | connect to suction line "brown" and apply vacuum of 400+50 mbar (max. pressure drop 6 mbar/min). |
Vacuum tester (019) | connect to vacuum unit (6) and apply vacuum of 300+50 mbar (max. pressure drop 5 mbar/min). |
Permissible loss of vacuum mbar/min
Model | 124, 201 |
Entire system at 400+50 mbar vacuum | 61) |
Individual parts at 300+50 mbar vacuum | 51) |
1) Maximum pressure drop
Special tool
Checking
-------------------------------
1 Turn ignition key on glow starter switch to
position "2".
2 Pull suction line (brown) from connector (arrow).
Model 124
Model 201
Vacuum supply directly from check valve of main
vacuum line.
Models 124 and 201 as of July 1987
3 Connect tester and apply vacuum of 400+50 mbar.
If the display on the pressure gauge fails to change, the valve for the glow starter switch is leaking.
If a vacuum drop of more than 6 mbar/min occurs on the pressure gauge, the valve (61c) on the glow starter switch is leaking.
Caution!
Before replacing the valve for the glow starter system and the vacuum unit of the injection pump, check hose lines and connections.
4 Renew valve on glow starter switch.
5 Turn ignition key on glow starter switch to
position "0".
If a vacuum drop occurs on the pressure gauge, the vacuum unit or the valve may be leaking.
6 In this case, disconnect tester from suction line (brown).
7 Pull control line (brown/blue) from connector (arrow).
Model 201
Standard version and
Model 201
California version
Model 124
Standard version
8 Connect tester to connector and apply vacuum of 300+50 mbar.
If a vacuum drop of more than 5 mbar/min occurs on the pressure gauge, the vacuum unit of the injection pump is leaking.
Caution!
Before replacing the vacuum unit, check hose lines and connectors.
9 Renew vacuum unit (07.1-220).
Odkazované dokumenty
- ra07016010001x
- ra07016010002x
- ra07016010003x
- ra07016010220x
- ra0701601a010x
- ra0701601a015x
- ra0701601b010x
- ra0701601b015x
- ra0701601c010x
- ra0701601c015x
- ra0701601d010x
- ra0701601e010x
- ra0701601f010x
- ra0701601g010x
- ra0701601h010x
- ra0701601i010x
- ra0701601j010x
- ra0701601k010x
- ra0701601l010x
- ra0701601m010x
- ra0701601n010x
- ra0701601o010x
- ra0701601p010x
- ra0701601pr02x
- ra0701601q010x
- ra0701601r010x
- ra0701601ta20x