07.1-102 Checking pneumatic idle speed increase
Job no. of Job Texts and Work Units or Standard Texts and Flat Rates 07-2009 |
1st version with 2 thermovalves
Engine | run to coolant temperature > 40 °C. |
Vacuum tester (019) | connect and check supply vacuum: set value 700 mbar. |
Thermovalve (128) (closes at approx. 17 °C) | check for leaks. |
Thermovalve (130) (opens at approx. 17 °C) | check for open passage. |
Vacuum unit idle speed increase | check for leaks. |
Ventilation line (black) | check for open passage. |
2nd version with 1 thermovalve
Engine | run to coolant temperature > 40 °C. |
Vacuum unit (019) | connect and check supply vacuum: |
Thermovalve (128a) (closes at approx. 30 °C) | check for leaks. |
Vacuum unit idle speed increase | check for leaks. |
Ventilation line (black) | check for open passage. |
Test values
Permissible loss of vacuum mbar/min
Model | 124, 201 |
Total system at 400+50 mbar vacuum | 61) |
Individual components at 300+50 mbar vacuum | 51) |
1) Max. pressure drop
Special tool
Note
Before carrying out this job check idle speed adjustment.
The vacuum unit (4) on the injection pump can only be renewed by a Bosch agent as the governor has to be dismantled and subsequently adjusted on a Bosch injection pump calibrating test bench.
Odkazované dokumenty
- ra07016010001x
- ra07016010002x
- ra07016010003x
- ra0701601a010x
- ra0701601a015x
- ra0701601b010x
- ra0701601b015x
- ra0701601c010x
- ra0701601c015x
- ra0701601d010x
- ra0701601e010x
- ra0701601f010x
- ra0701601g010x
- ra0701601h010x
- ra0701601i010x
- ra0701601j010x
- ra0701601k010x
- ra0701601l010x
- ra0701601m010x
- ra0701601n010x
- ra0701601o010x
- ra0701601p010x
- ra0701601pr02x
- ra0701601q010x
- ra0701601r010x
- ra0701601ta00x