GF83.70-W-3030A | "End heater operation upon exceeding cut-off threshold in partial load operation", function | 8.11.95 |
MODEL 950, 952, 953, 954 with CODE (H64) Hot water auxiliary heater "Eberspächer" D9W
W83.70-0017-09
1 Timer
2 Control module
3 Glow pin
4 Temperature sensor
5 Burner
6 Heat exchanger
7 Overheating sensor
V Combustion air
A Exhaust
KE Coolant inlet
KA Coolant outlet
KS Fuel
8 Coolant circulation pump
9 Burner housing
10 Flame sensor
11 Combustion air blower
12 Exhaust line with muffler
13 Combustion air line
14 Fuel metering pump
15 Automatic heater control panel
Function sequence
Heater switched on with timer (1) for auxiliary heater.
Heater operating in partial load range.
The heater is switched off by the control module (2) upon exceeding the maximum temperature for the coolant. The heater then switches to the cooling phase with shut-off delay:
- The fuel supply is interrupted immediately by switching off the fuel metering pump (14).
-----------------------------------------------------------------------------------------
- The combustion air blower (11) continues to run for
210 seconds cooling the combustion chamber and flushing out any combustion gases.
After completion of the cooling phase with shut-off delay the heater goes to the controlled shut-off phase:
- The blower for the vehicle heater continues to run.
- The coolant circulation pump (8) continues to run.
-----------------------------------------------------------------------------------------
Operating state upon exceeding maximum temperature
After the heater is switched off by the control module upon exceeding the maximum temperature the following components remain in operation:
Cooling phase with shut-off delay
Combustion air blower, low stage = 1850 rpm
Fuel metering pump = off
Coolant circulation pump = running
Blower for vehicle heater = running
Operating state upon completion of cooling phase with shut-off delay
After completing the cooling phase with shut-off delay the following heater components remain in operation:
Controlled shut-off phase
Combustion air blower = off
Fuel metering pump = off
Coolant circulation pump = running
Blower for vehicle heater = running
Burner housing | |||
Heat exchanger, location/purpose/design | |||
Auxiliary heater control module, location/purpose | |||
Coolant circulation pump, location/purpose/design | |||
Combustion air blower, location/purpose/design | |||
Glow pin, location/purpose/design | |||
Flame monitor, location/purpose/design | |||
Timer, location/purpose/design | |||
Fuel metering pump, location/purpose/design | |||
Coolant temperature sensor, location/purpose/design | |||
Overheating sensor, location/purpose/design |