"End heater operation upon exceeding cut-off threshold in partial load operation", function

Typ gf · téma 83.70 · verze 0102 · 1999-11-08

Platí pro: MODEL 950, 952, 953, 954 with CODE (H64) Hot water auxiliary heater "Eberspächer" D9W '

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 3 Nástavba › 83 Klimatizace › 83.70 Nezávislé topení, přídavné topení, přihřívač — Řada 950 · Řada 952 · Řada 953 · Řada 954

GF83.70-W-3030A

"End heater operation upon exceeding cut-off threshold in partial load operation", function

8.11.95

MODEL 950, 952, 953, 954 with CODE (H64) Hot water auxiliary heater "Eberspächer" D9W

"End heater operation upon exceeding cut-off threshold in partial load          
	operation", function

W83.70-0017-09

1 Timer
2 Control module
3 Glow pin
4 Temperature sensor
5 Burner
6 Heat exchanger
7 Overheating sensor

V Combustion air
A Exhaust
KE Coolant inlet
KA Coolant outlet
KS Fuel

8 Coolant circulation pump
9 Burner housing
10 Flame sensor
11 Combustion air blower
12 Exhaust line with muffler
13 Combustion air line
14 Fuel metering pump
15 Automatic heater control panel

Function sequence

Heater switched on with timer (1) for auxiliary heater.

Heater operating in partial load range.

The heater is switched off by the control module (2) upon exceeding the maximum temperature for the coolant. The heater then switches to the cooling phase with shut-off delay:

- The fuel supply is interrupted immediately by switching off the fuel metering pump (14).

-----------------------------------------------------------------------------------------

- The combustion air blower (11) continues to run for
210 seconds cooling the combustion chamber and flushing out any combustion gases.

After completion of the cooling phase with shut-off delay the heater goes to the controlled shut-off phase:

- The blower for the vehicle heater continues to run.

- The coolant circulation pump (8) continues to run.

-----------------------------------------------------------------------------------------

Operating state upon exceeding maximum temperature

After the heater is switched off by the control module upon exceeding the maximum temperature the following components remain in operation:

Cooling phase with shut-off delay

Combustion air blower, low stage = 1850 rpm

Fuel metering pump = off

Coolant circulation pump = running

Blower for vehicle heater = running

Operating state upon completion of cooling phase with shut-off delay

After completing the cooling phase with shut-off delay the following heater components remain in operation:

Controlled shut-off phase

Combustion air blower = off

Fuel metering pump = off

Coolant circulation pump = running

Blower for vehicle heater = running

Burner housing
Location/purpose/design

GF83.70-W-4000A

Heat exchanger, location/purpose/design

GF83.70-W-4017A

Auxiliary heater control module, location/purpose

GF83.70-W-4015A

Coolant circulation pump, location/purpose/design

GF83.70-W-4018A

Combustion air blower, location/purpose/design

GF83.70-W-4019A

Glow pin, location/purpose/design

GF83.70-W-4020A

Flame monitor, location/purpose/design

GF83.70-W-4021A

Timer, location/purpose/design

GF83.70-W-4022A

Fuel metering pump, location/purpose/design

GF83.70-W-4023A

Coolant temperature sensor, location/purpose/design

GF83.70-W-4024A

Overheating sensor, location/purpose/design

GF83.70-W-4025A