GF80.45-P-2009S | Convenience closing/opening with recirculated air button, function | 12.5.98 |
MODEL 215, 220
P80.45-2003-09
CAN messages:
1 Direction of convenience actuation:
Opening/closing
2 Opening/closing sliding roof
3 Opening/closing power windows
4 Position of power windows
N22 Automatic AC pushbutton control module
N69/1 Left front door control module
N69/2 Right front door control module
N69/3 Left rear door control module
N69/4 Right rear door control module
N70 Overhead control panel control module
5 Position of sliding/pop-up roof
M10/3 Left front power window motor
M10/4 Right front power window motor
M10/5 Left rear power window motor
M10/6 Right rear power window motor
M12 Sliding/pop-up roof drive assembly
Function prerequisites
Voltage not too low or too high
Sliding/pop-up roof and power windows synchronized
Convenience closing function via recirculated air button
Actuation of the recirculated air button in the automatic AC pushbutton control module (N22) for t > 1 s triggers the convenience closing function. The overhead control panel control module (N70) and the door control modules (N69/1, N69/2, N69/3, N69/4) receive the signal to automatically close the sliding/pop-up roof and the power windows from the automatic AC pushbutton control module (N22) via the CAN bus. Simultaneously the momentary roof and window positions are stored in the corresponding control module. To avoid excessive loads first the sliding/pop-up roof and then the windows are automatically closed.
Convenience opening function via recirculated air button
When the recirculated air button is pressed again for t > 1 s the sliding/pop-up roof and the power windows are moved to the previously stored positions.
Exception:
If some of the windows have been opened manually while the recirculated air mode was switched on, the windows remain in the set positions after completion of the recirculated air function.
Within the scope of the convenience closing feature the roof and window positions stored when the recirculated air button was pressed, are canceled when the ignition is switched off.