gf7229p3004a

Convenience opening of power windows function

Typ gf · téma 72.29 · verze 0103 · 2001-07-13

Platí pro: MODELS 202 as of 1.6.97, 208, 210.081 /281 (except 208.4), 210 (except 210.081 /281) as of 1.3.97

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 3 Nástavba › 72 Dveře › 72.29 Elektrická část dveří — Řada 202 · Řada 208 (modely 3**) · Řada 210 (modely 003, 004, 006, 007, 010, 015, 016, 017, 020, 025, 026, 035, 037, 045, 048, 053, 055, 061, 062, 063, 065, 070, 072, 074, 081, 082, 083, 206, 210, 215, 216, 217, 225, 226, 235, 237, 245, 248, 261, 262, 263, 265, 270, 272, 274, 281, 282, 283, 606, 610, 616, 617, 663)

GF72.29-P-3004A

Convenience opening of power windows function

22.1.97

MODELS 202 as of 1.6.97,
208, 210.081 /281 (except 208.4),
210 (except 210.081 /281) as of 1.3.97

Function prerequisites

No overvoltage/undervoltage

circuit 15 off and

circuit 15R off and

circuit 15c off.

Function

Each door control module (N69/1) or (N69/2), (MODELS 202/210 also N69/3 or N69/4) receives over CAN the request for

convenience opening and then actuates the power window motor. The motor is actuated until the door control module

-----------------------------------------------------------------------------------------

detects through position recognition that the window is completely open. The convenience opening function of the power window is also performed for non-normalized windows.

The convenience opening function of the power windows is aborted if

the request over CAN is no longer received or

lock-up of the power window is detected or

the function requirements listed above are no longer satisfied.

-----------------------------------------------------------------------------------------