GF72.29-P-3004A | Convenience opening of power windows function | 22.1.97 |
MODELS 202 as of 1.6.97,
208, 210.081 /281 (except 208.4),
210 (except 210.081 /281) as of 1.3.97
Function prerequisites
No overvoltage/undervoltage
circuit 15 off and
circuit 15R off and
circuit 15c off.
Function
Each door control module (N69/1) or (N69/2), (MODELS 202/210 also N69/3 or N69/4) receives over CAN the request for
convenience opening and then actuates the power window motor. The motor is actuated until the door control module
-----------------------------------------------------------------------------------------
detects through position recognition that the window is completely open. The convenience opening function of the power window is also performed for non-normalized windows.
The convenience opening function of the power windows is aborted if
the request over CAN is no longer received or
lock-up of the power window is detected or