GF72.29-P-4001A | Lock-up recognition of power windows, function | 12.12.96 |
MODELS 202 as of 1.6.97,
208, 210.081 /281 (except 208.4),
210 (except 210.081 /281) as of 1.3.97
Function
The door control module (N69/1) or (N69/2), (with MODELS 202/210 also N69/3 or N69/4), receives pulses from the power windows for the position recognition.
-----------------------------------------------------------------------------------------
If these pulses are absent during the actuation of the motor in the power window for more than 1 sec, then the door control module detects the lock-up of the motor and switches it off.
-----------------------------------------------------------------------------------------