gf0710s1040pd

Engine start-stop function

Typ gf · téma 07.10 · verze 0100 · 2017-11-08

Platí pro: Engine 699 in model 470, 471 with code MJ8 (ECO start/stop function)

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 1 Motor › 07 Příprava směsi › 07.10 Elektronické řízení motoru/Regulace motoru — Řada 470 · Řada 471

Platí také pro motory/převodovky: 699 ***

GF07.10-S-1040PD

Engine start-stop function

24.10.2017

Engine

699 in model 470, 471

with code MJ8 (ECO start/stop function)

Engine start-stop function

S07.10-0044-79

Block diagram

A1/1

Instrument cluster (KI) control unit

N93

Central gateway (CGW)

A40

Audio/COMAND control panel

N154

Climate control control unit

A40/1

Left lower control panel (LCPL [UBFL]) control unit

S2/3

KEYLESS GO start/stop button

A40/1s4

ECO start/stop function button

S40/3

Clutch pedal switch (with manual transmission)

B70/2

Crankshaft Hall sensor

S98/1s5

Defrosting button

K1/2

Idle start/stop relay 1

X11

Diagnostic connector

K1/3

Idle start/stop relay 2

CAN A

Telematics CAN

M1

Starter

CAN D

Diagnostic CAN

N3/33

CDI control unit

CAN E

Chassis CAN

N10/1

Signal acquisition and actuation module (SAM) control unit

CAN HMI

User interface CAN

N14

On-board electrical system management system control unit

CAN V

Vehicle CAN

N15/3

Electronic transmission control (EGS) control unit (with automatic transmission)

LIN A2

Telephone keypad LIN

N45

Transfer case control unit (VG) (with code ZG3 (Engageable all-wheel drive with gear reduction) or with code ZG4 (Permanent all-wheel drive with gear reduction))

A

Mercedes-Benz

N50

Fuse and relay module control unit (SRM)

B

Nissan

N80

Steering column tube module (MRM) control unit

C

Default

N83

DC/DC converter

D

Optional

N87/6

Radio (Audio/COMAND)

Function requirements, general

To enable the function, the on-board electrical system management system control unit checks the following function requirements:

Function switched on via ECO start/stop function button

Driver door closed

Seat belt lock closed

Engine hood closed

One-off exceedance of a vehicle speed of 20 km/h

Drive range "4L" not engaged (all-wheel drive)

Defrost button not actuated.

Rear window heater (R1) switched off

System diagnosis completed without faults

On-board electrical system battery (G1) sufficiently charged

On-board electrical system battery temperature  5 °C

Coolant temperature between 19 and 105 °C

Fuel temperature  90 °C

Diesel particulate filter (DPF) regeneration not active

Exhaust gas temperature < 670 °C

Engine Start/stop function, general points

For a stationary vehicle, the engine start/stop function automatically shuts off the engine and starts it again once the driver wants to drive off.

It is still possible to stop and start the engine in the conventional way.

Engine shutoff via engine start/stop function

Where the function requirements are fulfilled, the on-board electrical system management system control unit enables the engine start/stop function.

The engine is switched off and the indicator lamp in the ECO start/stop function button is switched on under the following conditions:

Vehicle speed  2 km/h

Steering manoeuvre within a rotation angle of 450 or < 100/s

Idling speed

Sufficient vacuum in brake booster

Transmission in neutral position (for manual transmission)

Clutch pedal not actuated (for manual transmission).

Drive range "D" engaged and service brake actuated (for automatic transmission)

To reduce the time for the engine restart, the CDI control unit detects the piston position during engine stop via the crankshaft Hall sensor.

Start engine via engine start/stop function

The engine is started and the indicator lamp in the ECO start/stop function button is switched off under the following conditions:

Clutch pedal actuated (for manual transmission).

Service brake no longer actuated (for automatic transmission).

The CDI control unit then starts the engine.

The engine is also independently (without driver action) force started if one of the indicated function requirements is no longer given.

Voltage stabilization

The on-board electrical system management system control unit transfers a corresponding signal to the DC/DC converter during engine start. This temporarily increases the on-board electrical system voltage to compensate for the voltage drop during engine start.

The brightness of the headlamps can change due to the voltage drop during engine start. They are not connected to the DC/DC converter.

Engine restart bypass relay control

The on-board electrical system management system control unit actuates the idle start-stop relay 1 and activates the idle start-stop relay 2. Once the restart conditions are fulfilled, the on-board electrical system management system control unit switches on the idle start-stop relay 1 for approx. 0.19 s during engine restart and briefly opens the idle start-stop relay 2. The voltage is thus directly transmitted to the starter. In this way, the on-board electrical system management system control unit facilitates a voltage stabilization of the battery.

Electrical function schematic for engine start/stop

PE07.10-S-2721-97PD

Overview of system components for common rail diesel injection (CDI)

GF07.16-S-9997PD

Odkazované dokumenty