be0732p200001c

Emissions inspection specified values, KE-Jetronic

Typ be · téma 07.32 · verze 0108 · 2011-09-09

Platí pro: ENGINE 116.964 /965, 117.964 /965 /968, 119.960 with CODE (620) Vehicles with catalytic converters

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 1 Motor › 07 Příprava směsi › 07.32 Systém vstřikování paliva zážehového motoru KE — Řada 117 (modely 965, 968)

EinPAS 15 Motor › 15.45 Management motoru › 15.45.1 Základní informace — Řada 117 (modely 965, 968)

Platí také pro motory/převodovky: 116 965, 119 960

BE07.32-P-2000-01C

Emissions inspection specified values, KE-Jetronic

ENGINES 116, 117, 119

Test values, emissions inspection specified values, KE-Jetronic

Number

Designation

Engine
116.964 up to 08/87
in model
107.046/047

BE07.32-P-2001-01C

-

Engine temperature

Oil

°C

60

Coolant

°C

-

Conditioning

Time

s

90

Rpm

rpm

3700

Number of cylinders

8

Number of pulses

per revolution

4

Idling speed

rpm

550 to 800

Ignition angle at
vacuum

with the engine idling

°KW v. OT

10 to 14

Lambda control

with the engine idling

%

-

Duty cycle

at higher speed: 1 rpm 2500

%

-

Alternative method

%

λ (λ2500)+515

Basic procedure

Interference factor

mbar

-

at engine speed

rpm

500 to 1100

Lambda control

Voltage at idle speed

V

2 to 10

CO specification

at higher idle speed: 1 rpm 2200...2800

%

0.3

Lambda mixture specification

at higher idle speed: 1 rpm 2200...2800


0.97 to 1.03

CO specification

with the engine idling

%

0.5

Test values, emissions inspection specified values, KE-Jetronic

Number

Designation

Engine
116.964 as of 09/87
in model
107.047

Engine
116.965 as of 09/87
in model 126.034/035/046

BE07.32-P-2001-01C

-

Engine temperature

Oil

°C

60

60

Coolant

°C

-

-

Conditioning

Time

s

90

90

Rpm

rpm

3700

3700

Number of cylinders

8

8

Number of pulses

per revolution

4

4

Idling speed

rpm

550 to 800

550 to 800

Ignition angle at
vacuum

with the engine idling

°KW v. OT

10 to 14

5 to 20

Lambda control

with the engine idling

%

-

-

Duty cycle

at higher speed: 1 rpm 2500

%

-

-

Alternative method

%

λ (λ2500)10

λ (λ2500)10

Basic procedure

Interference factor

mbar

-

-

at engine speed

rpm

500 to 1100

500 to 1100

Lambda control

Voltage at idle speed

V

2 to 10

2 to 10

CO specification

at higher idle speed: 1 rpm 2200...2800

%

0,3

0.3

Lambda mixture specification

at higher idle speed: 1 rpm 2200...2800


0.97 to 1.03

0.97 to 1.03

CO specification

with the engine idling

%

0.5

0.5

Test values, emissions inspection specified values, KE-Jetronic

Number

Designation

Engine
116.965 up to 08/87
in model
126.034/035/046

BE07.32-P-2001-01C

-

Engine temperature

Oil

°C

60

Coolant

°C

-

Conditioning

Time

s

90

Rpm

rpm

3700

Number of cylinders

8

Number of pulses

per revolution

4

Idling speed

rpm

550 to 800

Ignition angle at
vacuum

with the engine idling

°KW v. OT

5 to 20

Lambda control

with the engine idling

%

-

Duty cycle

at higher speed: 1 rpm 2500

%

-

Alternative method

%

λ (λ2500)+515

Basic procedure

Interference factor

mbar

-

at engine speed

rpm

500 to 1100

Lambda control

Voltage at idle speed

V

2 to 10

CO specification

at higher idle speed: 1 rpm 2200...2800

%

0.3

Lambda mixture specification

at higher idle speed: 1 rpm 2200...2800


0.97 to 1.03

CO specification

with the engine idling

%

0.5

Test values, emissions inspection specified values, KE-Jetronic

Number

Designation

Engine
117.964 as of 09/87
in model
107.046

Engine
117.965 as of 09/87
in model 126.036/037/044

BE07.32-P-2001-01C

-

Engine temperature

Oil

°C

60

60

Coolant

°C

-

-

Conditioning

Time

s

90

90

Rpm

rpm

3700

3700

Number of cylinders

8

8

Number of pulses

per revolution

4

4

Idling speed

rpm

550 to 800

550 to 800

Ignition angle at
vacuum

with the engine idling

°KW v. OT

10 to 14

5 to 20

Lambda control

with the engine idling

%

-

-

Duty cycle

at higher speed: 1 rpm 2500

%

-

-

Alternative method

%

λ (λ2500)10

λ (λ2500)10

Basic procedure

Interference factor

mbar

-

at engine speed

rpm

500 to 1100

500 to 1100

Lambda control

Voltage at idle speed

V

2 to 10

2 to 10

CO specification

at higher idle speed: 1 rpm 2200...2800

%

0.3

0.3

Lambda mixture specification

at higher idle speed: 1 rpm 2200...2800


0.97 to 1.03

0.97 to 1.03

CO specification

with the engine idling

%

0.5

0.5

Test values, emissions inspection specified values, KE-Jetronic

Number

Designation

Engine
117.965 up to 08/87
in model
126.036/037/044

BE07.32-P-2001-01C

-

Engine temperature

Oil

°C

60

Coolant

°C

-

Conditioning

Time

s

90

Rpm

rpm

3700

Number of cylinders

8

Number of pulses

per revolution

4

Idling speed

rpm

550 to 800

Ignition angle at
vacuum

with the engine idling

°KW v. OT

5 to 20

Lambda control

with the engine idling

%

-

Duty cycle

at higher speed: 1 rpm 2500

%

-

Alternative method

%

λ (λ2500)+515

Basic procedure

Interference factor

mbar

-

at engine speed

rpm

500 to 1100

Lambda control

Voltage at idle speed

V

2 to 10

CO specification

at higher idle speed: 1 rpm 2200...2800

%

0.3

Lambda mixture specification

at higher idle speed: 1 rpm 2200...2800


0.97 to 1.03

CO specification

with the engine idling

%

0.5

Test values, emissions inspection specified values, KE-Jetronic

Number

Designation

Engine
117.96 in model 463.228

BE07.32-P-2001-01C

-

Engine temperature

Oil

°C

60

Coolant

°C

-

Conditioning

Time

s

90

Rpm

rpm

3700

Number of cylinders

8

Number of pulses

per revolution

4

Idling speed

rpm

550 to 800

Ignition angle at
vacuum

with the engine idling

°KW v. OT

5 to 20

Lambda control

with the engine idling

%

-

Duty cycle

at higher speed: 1 rpm 2500

%

-

Alternative method

%

λ (λ2500)+515

Basic procedure

Interference factor

mbar

-

at engine speed

rpm

500 to 1100

Lambda control

Voltage at idle speed

V

2 to 10

CO specification

at higher idle speed: 1 rpm 2200...2800

%

0.3

Lambda mixture specification

at higher idle speed: 1 rpm 2200...2800


0.97 to 1.03

CO specification

with the engine idling

%

0.5

Test values, emissions inspection specified values, KE-Jetronic

Number

Designation

Engine
117.968 up to 08/87
in model
126.038/039/045

BE07.32-P-2001-01C

-

Engine temperature

Oil

°C

60

Coolant

°C

-

Conditioning

Time

s

90

Rpm

rpm

3700

Number of cylinders

8

Number of pulses

per revolution

4

Idling speed

rpm

550 to 800

Ignition angle at
vacuum

with the engine idling

°KW v. OT

5 to 20

Lambda control

with the engine idling

%

-

Duty cycle

at higher speed: 1 rpm 2500

%

-

Alternative method

%

λ (λ2500)+515

Basic procedure

Interference factor

mbar

-

at engine speed

rpm

500 to 1100

Lambda control

Voltage at idle speed

V

2 to 10

CO specification

at higher idle speed: 1 rpm 2200...2800

%

0.3

Lambda mixture specification

at higher idle speed: 1 rpm 2200...2800


0.97 to 1.03

CO specification

with the engine idling

%

0.5

Test values, emissions inspection specified values, KE-Jetronic

Number

Designation

Engine
117.968 as of 08/87
in model 126.038/039/045

Engine
119.960 in model 129.066

BE07.32-P-2001-01C

-

Engine temperature

Oil

°C

60

60

Coolant

°C

-

-

Conditioning

Time

s

90

90

Rpm

rpm

3700

3700

Number of cylinders

8

8

Number of pulses

per revolution

4

4

Idling speed

rpm

550 to 800

550 to 800

Ignition angle at
vacuum

with the engine idling

°KW v. OT

5 to 20

14 to 18

Lambda control

with the engine idling

%

-

50 (20)

Duty cycle

at higher speed: 1 rpm 2500

%

-

50 (20)

Alternative method

%

λ (λ2500)10

-

Basic procedure

Interference factor

mbar

-

>450

at engine speed

rpm

500 to 1100

500 to 1100

Lambda control

Voltage at idle speed

V

-

2 to 10

CO specification

at higher idle speed: 1 rpm 2200...2800

%

0.3

0.3

Lambda mixture specification

at higher idle speed: 1 rpm 2200...2800


0.97 to 1.03

0.97 to 1.03

CO specification

with the engine idling

%

0.5

0.5