1 | Filter drier |
2 | Clip |
3 | Refrigerant line |
4 | Filling connection |
5 | Protective nut |
6 | Electrical shutoff valve |
T83.50-0018-05
| Remove/install | ||
Danger | Risk of explosion caused by welding or soldering work on closed air conditioning system. Risk of poisoning caused by inhaling overheated refrigerant vapors. Risk of injury to skin and eyes caused by contact with liquid refrigerant. | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear safety glasses and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been drained. | |
Danger | Risk of death caused by falling from vehicle roof. Risk of injury to other persons caused by falling objects during work in roof area. | ||
Topical note | Procedure for a damaged or leaky air conditioning system | ||
Topical note | Protect air conditioning circuit and components from moisture when carrying out repair work | ||
Notes on handling refrigerant R134a | |||
1 | Remove paneling of condenser unit | ||
2 | Remove protective nut (5) over manually operated shutoff valve | ||
3 | Screw in manually operated shutoff valve completely | When the A/C mode is switched off, the electric shutoff valve (6) of the cooling circuit is automatically disabled. | |
4 | Connect A/C suction and recycling equipment to filler connection (4) | Pay attention to the operating instructions of the A/C suction and recycling equipment. | |
5 | Empty closed-off circuit of filter drier (1) via filler connection (4) using A/C suction and recycling equipment | Installation: Evacuate closed-off circuit of filter drier (1) via filler connection (4) using A/C suction and recycling equipment for at least 15 minutes and check for leaktightness. | |
6 | Loosen clamp (2) | ||
7 | Detach refrigerant lines (3) from filter drier (1) | ||
| Compressor oils (specification 362.0) | ||
Installation: Use new sealing rings. Coat sealing rings with compressor oil before installation. | |||
Refrigerant line to filter drier | |||
Warning | Risk of injury caused by damaged assemblies filled with refrigerant | Wear protective clothing, safety gloves and safety glasses. | |
8 | Remove and dispose of filter drier (1) | Installation: | |
9 | Install in the reverse order | ||
10 | Check refrigerant level of air conditioning system | ||
| |||
11 | Perform function test | ||
| Air conditioning system - function check |
Odkazované dokumenty
- ah8330n000301a Pokyny k manipulaci s chladivem R134a
- ah8330n000401a Postup při poškozené, resp. netěsné klimatizaci
- ah8330n000501a Ochrana okruhu a součástí klimatizace při opravárenských pracích před vlhkostí
- ap8300t8352aa
- ap8330t8312aa
- ar8350t5000aa
- as6500z000201a Nebezpečí ohrožení života pádem ze střechy vozidla. Nebezpečí poranění druhých osob padajícími předměty při pracích v oblasti střechy
- as8300z000101a Nebezpečí exploze při svářečských nebo pájecích pracích na uzavřené klimatizaci. Nebezpečí otravy při vdechnutí přehřátých výparů chladiva. Nebezpečí poranění při kontaktu očí a kůže s tekutým chladivem
- as8661z000101a Nebezpečí poranění v důsledku poškození agregátů plněných chladicím prostředkem
- bb0040p036200a Kompresorové oleje (specifikace 362.0)