AR83.40-P-6730TX | Remove/install multifunction sensor | 13.7.04 |
MODEL 219.3 with CODE (581) Convenience automatic air conditioning
P83.40-2881-06
1 Electrical connector
2 Sensor surfaces
B31 C-AAC multifunction sensor
| Remove/Install | ||
1 | Open engine hood and raise to vertical position | ||
2 | Unclip C-AAC multifunction sensor (B31) from water collector | Installation: The sensor surfaces (2) must point toward the water collector. Ensure that the electrical line is correctly routed. | |
3 | Unplug the electrical connector (1) from the C-AAC multifunction sensor (B31) and remove the C-AAC multifunction sensor (B31) | ||
4 | Install in the reverse order |