AR83.30-D-5520A | Remove and install expansion valve | 12.7.10 |
MODEL 901.0 /3 /4, 902.0 /3 /4, 903.0 /3 /4, 904.0 /3 /4 with CODE (H06) Air conditioning
D83.30-0007-06
1 Refrigerant lines for evaporator
2 Expansion valve
3 Screw
4 Refrigerant lines at intake side
pressure side
5 Nut
Modification notes
9.10.03 | Repair procedure has been revised | Step 2 (unscrew/screw on connection bracket at evaporator) deleted |
| Remove/Install | ||
Danger! | Risk of explosion from welding or soldering work on closed air conditioning system. Risk of poisoning. Inhaling overheated refrigerant vapors may be toxic. Risk of injury. Contact with liquid refrigerant may result in injury to the skin and eyes. | Never perform welding work on or near a closed air conditioning system. No smoking or open flames. Wear eye protection and protective gloves. Work only in well ventilated areas. Carry out repair work on the air conditioning system circuit only after the system has been discharged. | |
| Protect air conditioning circuit and components from moisture when carrying out repair work | All models fitted with air conditioning | |
1 | Discharge air conditioning system | ||
2 | Unscrew nut (5) and refrigerant lines (4) | Installation: Use new sealing rings. | |
3 | Unscrew bolts (3) and remove expansion valve (2) | Installation: Use new sealing rings. | |
4 | Install in the reverse order | ||
5 | Evacuate air conditioning system, leak test | ||
6.1 | Fill air conditioning system, replenish (gaseous) | ||
6.2 | Fill air conditioning system (liquid) |