AR82.10-P-4011EA | Check air-operated headlamp range adjustment | 28.1.09 |
MODEL 170, 202, 210 except CODE (491) USA version
P82.10-0021-01
A Light-dark boundary position 0
B Light-dark boundary position 3
| Check | ||
| Pneumatic headlamp range adjustment, function | ||
1 | Check and correct the adjustment of the headlamps | ||
2 | Move headlamp range controller from position 0 to position 3 | Light-dark boundary changes from A to B | |
Check vacuum system of headlamp range adjustment | |||
3 | Adjust knurled washer or measurement screen of the headlamp setting test equipment until the light-dark boundary (B) is reached | If the specified value on the adjustment scale on the headlamp adjustment testing unit is not reached: | |
Check ease of movement of the reflector and travel of the actuator (model 202 up to 31.08.96) | |||
Check ease of movement of the reflector (model 170, 202 as of 01.09.96, 210) | |||
Check travel of the actuator (model 170, 202 as of 01.09.96, 210) | |||
Check vacuum system of headlamp range adjustment |
Test and adjustment values for exterior lights
Number | Designation | Model 170 except | Model 202 except | ||
BE82.10-P-1001-01A | Vacuum values of pneumatic headlamp range adjustment | Position 0 | mbar | 400 30 | 400 30 |
Position 1 | mbar | 290 30 | 290 30 | ||
Position 2 | mbar | 200 30 | 200 30 | ||
Position 3 | mbar | 50 30 | 50 30 | ||
BE82.10-P-1002-01A | Actuator adjustment travel of the pneumatic headlamp range adjustment | Position 0 | mm | 0.0 | 0.0 |
Position 1 | mm | 0,95 | 0,95 | ||
Position 2 | mm | 1.7 | 1.7 | ||
Position 3 | mm | 3.0 | 3.0 | ||
BE82.10-P-1003-01A | Specified value for relocation of light-dark boundary on adjusting scale of headlamp adjustment testing unit | cm | 3348 | 33-48 | |
Test and adjustment values for exterior lights
Number | Designation | Model 210 except | ||
BE82.10-P-1001-01A | Vacuum values of pneumatic headlamp range adjustment | Position 0 | mbar | 400 30 |
Position 1 | mbar | 290 30 | ||
Position 2 | mbar | 200 30 | ||
Position 3 | mbar | 50 30 | ||
BE82.10-P-1002-01A | Actuator adjustment travel of the pneumatic headlamp range adjustment | Position 0 | mm | 0.0 |
Position 1 | mm | 0,95 | ||
Position 2 | mm | 1.7 | ||
Position 3 | mm | 3.0 | ||
BE82.10-P-1003-01A | Specified value for relocation of light-dark boundary on adjusting scale of headlamp adjustment testing unit | cm | 3348 | |
201 589 13 21 00
Vacuum tester
Odkazované dokumenty
- ap8210p8260a Zkontrolovat, seřídit nastavení světlometů
- ar8210p401101ea
- ar8210p401102za
- ar8210p401201a
- ar8210p401202a
- gf8210p0001aa