AR82.00-P-0500MCC | Perform software update for audio units | 21.2.12 |
MODEL 451.3 /4 with CODE (527) High-Line radio
Danger! | Risk of explosion caused by escaping oxyhydrogen gas. Risk of injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte (contains diluted sulfuric acid) or metal spatter due to short circuit. Risk of burn injuries caused by short circuit. Risk of poisoning caused by swallowing battery electrolyte (contains diluted sulfuric acid) or absorption of lead over the skin or orifices | No fire, sparks, open flames or smoking. Wear acid-resistant gloves and clothing and safety glasses with side guards. Do not place any conductive objects on the battery and avoid any short circuit from battery positive to ground. Only fill liquid battery electrolyte (diluted sulfuric acid) into suitable and appropriately marked containers. | |
1 | Connect charger to battery | Use the charger to ensure that an adequate power supply (min. 12.5 V) is provided for the on-board electrical system battery. | |
| Notes on battery | ||
2 | Disconnect all external data carriers from smart Premium radio | ||
3 | Switch on smart Premium radio | ||
4 | Check software release of smart Premium radio | Selection through: Extras Options System settings Product information | |
5 | Fold up display of smart Premium radio and insert secure digital (SD) card, then close display again | The current software release for the SD card has to be assured, check beforehand if necessary. | |
6 | Read out SD card data | To do so press "OFF" button for 10 to 12 seconds, until the illumination for the smart Premium radio and the button illumination have gone out. Then switch on the smart Premium radio again. | |
7 | Run update procedure | Confirm with "OK". The software update runs automatically and takes up to 50 minutes. The display opens during the software update and closes again after the software update has been completed. | |
8 | Calibrate display | By pressing the five subsequent crosses on the screen. | |
9 | Open display of smart Premium radio and remove SD card, then close display again | ||
10 | Reset smart Premium radio to factory settings | Selection through: Extras Options System settings Factory settings | |
11 | Check software release of smart Premium radio | Selection through: Extras Options System settings Product information | |
12 | Operate smart Premium radio | Restore language settings, personal settings, Bluetooth connections, etc.. | |
Danger! | Risk of explosion caused by escaping oxyhydrogen gas. Risk of injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte (contains diluted sulfuric acid) or metal spatter due to short circuit. Risk of burn injuries caused by short circuit. Risk of poisoning caused by swallowing battery electrolyte (contains diluted sulfuric acid) or absorption of lead over the skin or orifices | No fire, sparks, open flames or smoking. Wear acid-resistant gloves and clothing and safety glasses with side guards. Do not place any conductive objects on the battery and avoid any short circuit from battery positive to ground. Only fill liquid battery electrolyte (diluted sulfuric acid) into suitable and appropriately marked containers. | |
13 | Connect charger to battery | ||
| Notes on battery | ||
14 | Operate navigation system | To do so, drive the vehicle in the open to enable the satellite data to be picked up. |
Odkazované dokumenty
- ah5410p000101a Upozornění k akumulátoru
- ah5410p000101a
- as5410z000101a Nebezpečí požáru/exploze kvůli zkratu a unikajícímu výbušnému plynu. Nebezpečí popálení/poranění poleptáním očí, pokožky a sliznic elektrolytem / elektrolytovou mlhou akumulátoru při zkratu nebo následkem světelné