AR54.18-T-0002AA | Disconnecting and connecting electrical cables from battery | 16.2.12 |
MODEL 671.015 /020 /021 /030 /042 /332 /333
T54.18-0033-01
1 Battery tray lock
Danger! | Risk of explosion caused by escaping oxyhydrogen gas. Risk of injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte (contains diluted sulfuric acid) or metal spatter due to short circuit. Risk of burn injuries caused by short circuit. Risk of poisoning caused by swallowing battery electrolyte (contains diluted sulfuric acid) or absorption of lead over the skin or orifices | No fire, sparks, open flames or smoking. Wear acid-resistant gloves and clothing and safety glasses with side guards. Do not place any conductive objects on the battery and avoid any short circuit from battery positive to ground. Only fill liquid battery electrolyte (diluted sulfuric acid) into suitable and appropriately marked containers. | |
| Disconnecting | ||
1 | Switch off ignition | ||
2 | Open left maintenance flap behind the front axle | ||
3 | Turn manual vehicle power supply switch to "0" | ||
4 | Remove battery tray lock (1) and pull out batteries with battery tray | ||
5 | Disconnect battery terminals | Ensure that no accidental contact can occur between the battery terminals. | |
| Battery notes | All models | |
| Inspect | ||
6 | Check all electrical contacts for damage | Replace parts or batteries if necessary. | |
| Connecting | ||
7 | Connect battery terminals | ||
8 | Push in batteries with battery tray and lock | ||
9 | Turn manual vehicle power supply switch to "1" | ||
10 | Set tachograph, clock and radio | See Operating Instructions |