Check | |||
Danger | Risk of fire/risk of explosion due to short circuit and escaping oxyhydrogen gas. Risk of (burn) injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte/mist, short circuit and arcing. Risk of poisoning caused by swallowing battery electrolyte or absorption of lead through the skin or body orifices. Risk of death due to voltage U >= 30 V AC and U >= 60 V DC. | No fires, sparks, open flames, or smoking. Wear acid-resistant gloves, clothing, and glasses. Pour battery acid only into suitable and appropriately marked containers. | |
Topical note | Notes on battery | ||
1 | Read out fault memory | ||
| |||
Rectify faults in control units. | |||
2 | Open front hood and remove luggage compartment tray | ||
3 | Visual inspection for external leakage | If leaks are found, replace battery. | |
4 | Check battery |
| |
Topical note | Notes on battery | ||
Battery tester | |||
5 | Check fluid level | If necessary, refill with distilled water. |