| Remove | ||
Danger | Risk of fire/risk of explosion due to short circuit and escaping oxyhydrogen gas. Risk of (burn) injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte/mist, short circuit and arcing. Risk of poisoning caused by swallowing battery electrolyte or absorption of lead through the skin or body orifices. Risk of death due to voltage U >= 30 V AC and U >= 60 V DC. | No fires, sparks, open flames, or smoking. Wear acid-resistant gloves, clothing, and glasses. Pour battery acid only into suitable and appropriately marked containers. | |
Topical note | Notes on battery | ||
1 | Connect STAR DIAGNOSIS and read out fault memory | ||
| |||
Delete fault memory; rectify faults if necessary. | |||
2 | Remove foot support on passenger side |
| |
Right-hand drive vehicles | |||
| Check | ||
3 | Visual inspection of battery for external leakage |
| |
Right-hand drive vehicles | |||
If leaks are found, battery must be replaced. Refer to: | |||
| |||
Remove/install battery | |||
4 | Check fluid level; correct if necessary | ||
| Except model 451.334/380, 451.480, not if the battery was replaced. | ||
5 | Check battery | Cold cranking amps | |
Battery capacity 42 Ah | |||
Battery capacity 60 Ah VRLA/AGM | |||
Battery capacity 61 Ah | |||
Battery capacity 62 Ah | |||
| Install | ||
6 | Install foot support at front passenger side |
| |
Right-hand drive vehicles |
Test and adjustment values for battery |
Number | Designation | Model all (4xWD, CAR, smart) | |||
BE54.10-P-1009-01A | Battery capacity 62 Ah | Battery test at 20 °C | Acid density | kg/dm3 | 1,24 |
Maximum permissible difference between individual battery cells | kg/dm3 | 0,04 | |||
Load current | A | 190 | |||
Load time | s | 10 | |||
Voltage | V | 10 | |||
Cold cranking amps | As per EN | A | 480 |
Odkazované dokumenty
- ad0000p200004mcc
- ah5410p000101a Upozornění k akumulátoru
- ah5410p000101a
- ap5410p5410mcc Kontrola, vyrovnání hladiny elektrolytu akumulátorů
- ar5410p0005mcc
- ar5410p0005mce
- ar5410p112901a Zkontrolovat akumulátor
- ar6830p1340mcc
- ar6830p1340mce
- as5410z000101a Nebezpečí požáru/exploze kvůli zkratu a unikajícímu výbušnému plynu. Nebezpečí popálení/poranění poleptáním očí, pokožky a sliznic elektrolytem / elektrolytovou mlhou akumulátoru při zkratu nebo následkem světelné