ar5410m0007a

Remove/install additional battery

Typ ar · téma 54.10 · verze 0101 · 2012-02-22

Platí pro: MODEL 905.613 Minibus Sprinter low floor 6 t, with hydraulic lowering system at the front axle

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 2 Podvozek › 54 Elektrické zařízení, výstroj a přístroje › 54.10 Akumulátor, zdroj napětí, měnič napětí — Řada 905 (modely 613)

EinPAS 25 Palubní síť/síť/multifunkční systém › 25.20 Elektrická síť vozidla › 25.20.20 Akumulátor — Řada 905 (modely 613)

AR54.10-M-0007A

Remove/install additional battery

15.2.12

MODEL 905.613
Minibus Sprinter low floor 6 t,
with hydraulic lowering system at the front axle

Remove/install additional battery

M68.30-0009-11

1 Cover

2 Floor panel

Remove/install additional battery

M54.10-0022-11

3 Additional battery

4 Venting hose

5 Positive line

6 Bracket

7 Ground line

Remove/install

Danger!

Risk of explosion caused by escaping oxyhydrogen gas. Risk of injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte (contains diluted sulfuric acid) or metal spatter due to short circuit. Risk of burn injuries caused by short circuit. Risk of poisoning caused by swallowing battery electrolyte (contains diluted sulfuric acid) or absorption of lead over the skin or orifices

No fire, sparks, open flames or smoking.

Wear acid-resistant gloves and clothing and safety glasses with side guards.

Do not place any conductive objects on the battery and avoid any short circuit from battery positive to ground.

Only fill liquid battery electrolyte (diluted sulfuric acid) into suitable and appropriately marked containers.

AS54.10-Z-0001-01A

Notes on battery

AH54.10-P-0001-01A

1

Switch off hydraulic lowering system

2

Remove cover (1) of additional battery (3)

3

Detach ground line (7) from additional battery (3)

4

Detach positive line (5) from additional battery (3)

5

Disconnect vent hose (4) from additional battery (3)

6

Remove both brackets (6)

7

Remove additional battery (3)

If the additional battery (3) which has been removed has to be disposed of, observe disposal regulations:

Dispose of battery

OS54.10-P-0001-01Z

8

Install in the reverse order

Odkazované dokumenty