W42.60-0055-11
1 Paneling
2 Parking brake valve
3 Compressed-air connection, venting
4 Compressed-air connection, spring-loaded cylinder
5 Compressed-air connection, supply pressure
| Remove/Install | ||
1 | Discharge compressed-air system | ||
2 | Remove paneling (1) from parking brake valve (2). | ||
3 | Remove parking brake valve (2). | ||
4 | Label compressed-air connection, venting (3), compressed-air connection, spring-loaded cylinder( 4), and compressed-air connection, supply pressure (5) according to labeling on parking brake valve (2) and detach. | With compressed air connector system "VOSS 230". | |
With compressed air connector system "VOSS 232" (NG 8, 12) or "SCHÄFER SDF" (NG 6). | |||
Installation: Check O-rings, install new O-rings if necessary, and note marking. | |||
| Notes on compressed air connector systems | ||
5 | Install in the reverse order | ||
6 | Fill compressed-air system | Allow the engine to run until the brake system comes up to pressure. |
Odkazované dokumenty
- ah0018n000101a Pokyny k systémům konektorových spojů tlakového vzduchu
- ar4210w0900a Demontáž, montáž konektorového spoje tlakovzdušného potrubí
- ar4210w0900c Demontáž, montáž tlakovzdušného nástrčného spoje