AR27.19-D-4980A | Remove/install pilot bushing of electrohydraulic controller unit | 15.2.12 |
TRANSMISSION 722.681 in MODEL 902.6, 903.6, 904.6, 905.6
TRANSMISSION 722.681 in MODELS WD1, WD2, WD3, WD6, WD7, XD1, XD2, XD3, XD4, XD5, XD6, XD7, YD1, YD2, YD3, YD4, YD5, YD6, YD7
D27.19-1124-04
1 O-rings
2 Pilot bushing
3 Screw
| Remove/install | ||
Danger! | Risk of explosion caused by escaping oxyhydrogen gas. Risk of injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte (contains diluted sulfuric acid) or metal spatter due to short circuit. Risk of burn injuries caused by short circuit. Risk of poisoning caused by swallowing battery electrolyte (contains diluted sulfuric acid) or absorption of lead over the skin or orifices | No fire, sparks, open flames or smoking. Wear acid-resistant gloves and clothing and safety glasses with side guards. Do not place any conductive objects on the battery and avoid any short circuit from battery positive to ground. Only fill liquid battery electrolyte (diluted sulfuric acid) into suitable and appropriately marked containers. | |
1 | Disconnect battery ground line | Isolate ground lead to prevent accidental contact. | |
| Notes on battery | ||
2 | Detach electrical connector. | ||
3 | Unscrew bolt (3) and remove pilot bushing (2) | Catch oil running out. | |
4 | Install in the reverse order |
Odkazované dokumenty
- ah5410p000101a Upozornění k akumulátoru
- ah5410p000101a
- ar2719d075001b Odpojení, zapojení elektrických konektorových spojů u automatické převodovky
- as5410z000101a Nebezpečí požáru/exploze kvůli zkratu a unikajícímu výbušnému plynu. Nebezpečí popálení/poranění poleptáním očí, pokožky a sliznic elektrolytem / elektrolytovou mlhou akumulátoru při zkratu nebo následkem světelné