Remove/install pressure limiting valve at air controller unit of the exhaust
aftertreatment system
Typ ar · téma 14.40 · verze 0301 · 2019-11-08
Platí pro: Engine 924.9 in model 368, 384.0/2, 685.282/284/289/290 with code MS5 (Euro V) Engine 926.9 in model 368, 382.17/18, 384.0 with code MS5 (Euro V)
Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.
After engine shutdown, compressed air continues flowing through some compressed air lines for approximately 3 minutes. For this reason, start working on the compressed air control unit, after this time has elapsed.
Firstly, slacken the connection screw (4) in two turns to release the pressure of the system and then remove it completely.