ar1440b2016a

Remove/install pressure limiting valve at air controller unit of the exhaust aftertreatment system

Type ar · topic 14.40 · version 0301 · 2019-11-08

Applies to: Engine 924.9 in model 368, 384.0/2, 685.282/284/289/290 with code MS5 (Euro V) Engine 926.9 in model 368, 382.17/18, 384.0 with code MS5 (Euro V)

Where it sits

Function group 1 Engine › 14 Exhaust manifold, engine brake, emission control system › 14.40 Exhaust aftertreatment, AdBlue — Series 368 · Series 382 (models 17*, 18*) · Series 384 (models 0**, 2**) · Series 685 (models 282, 284, 289, 290)

EinPAS 15 Engine › 15.40 Exhaust system/exhaust aftertreatment › 15.40.13 Line/hose/valve — Series 368 · Series 382 (models 17*, 18*) · Series 384 (models 0**, 2**) · Series 685 (models 282, 284, 289, 290)

Also applies to engines/gearboxes: 924 9**, 926 9**

AR14.40-B-2016A

Remove/install pressure limiting valve at air controller unit of the exhaust aftertreatment system

23.10.2019

Engine

924.9 in model 368, 384.0/2, 685.282/284/289/290

with code MS5 (Euro V)

Engine

926.9 in model 368, 382.17/18, 384.0

with code MS5 (Euro V)

Remove/install pressure limiting valve at air controller unit of the exhaust    
	aftertreatment system

Represented on vehicle 382.177

1

Compressed air inlet

2

Compressed air outlet

3

Connection bolt

4

Connection bolt

5

Fastening bolt

6

Pressure limiting valve with quick discharge (33.03)

B14.40-0074-11

Remove/install

1

Removing the compressed air inlet line (1)

Topical note

Notes on self-locking nuts and bolts

AH00.00-N-0001-01A

Notes on compressed air connection systems

AH00.18-N-0001-01A


After engine shutdown, compressed air continues flowing through some compressed air lines for approximately 3 minutes.
For this reason, start working on the compressed air control unit, after this time has elapsed.

Firstly, slacken the connection screw (4) in two turns to release the pressure of the system and then remove it completely.

.Compressed air connection system "VOSS 232"

*BA00.18-B-1002-01A

2

Removing the compressed air outlet line (2)

Firstly, slacken the connection screw (3) in two turns to release the pressure of the system and then remove it completely.

.Compressed air connection system "VOSS 232"

*BA00.18-B-1002-01A

3

Remove the pressure limiting valve with quick discharge (6), unscrewing the fastening screws (5)

.Pressure limiting valve on support

*BA14.40-B-1019-02B

4

Installation in reverse order

5

Charge the compressed air pressure system to service pressure

Compressed air piping

Number

Designation

Model all (BUS, TRUCK)

BA00.18-B-1002-01A

Compressed air connection system "VOSS 232"

M16

Nm

14

M14

Nm

14

M22

Nm

14

Exhaust gas after-treatment

Number

Designation

Engine 924.9, 926.9 except Liquid Only

BA14.40-B-1019-02B

Pressure limiting valve on support

M8

Nm

20

Referenced documents