AR07.15-G-2000-23CI | Install testing/measuring equipment for leak testing of fuel system in low-pressure fuel circuit | ||
Danger | Risk of explosion caused by fuel igniting, risk of poisoning caused by inhaling and swallowing fuel as well as risk of injury to eyes and skin caused by contactwith fuel. | No fires, sparks, open flames or smoking. Pour fuels into suitable and appropriately marked containers only. | |
Note on calculation of tightening torque when using insertion or socket tools with various effective lengths | |||
| Plug for fuel line |
123 589 04 21 18
High-pressure hose
541 589 00 91 00
Adaptation parts
541 589 02 21 00
Tester
Adaptation parts consist of a set of separate parts, these are used together with the high-pressure hose in the following operation steps.
1 | Install test equipment (2) on fuel filter housing . |
2 | Disconnect fuel return line (3) and fuel feed line (4) at connection and remove O-ring at connector coupling. |
For this purpose, release retaining cap, press together retainer and pull plug out of connector coupling. Do not damage O-rings. |
3 | Seal fuel return line (3) with self-produced end cap (5). |
4 | Install adapter (1.2) and compressed-air filling line with stopcock (1.1) on fuel feed line (4). |
1.1 | Compressed air filling line with stopcock and banjo union |
1.2 | Adapter element |
2 | Tester |
3 | Fuel return line |
4 | Fuel feed line |
5 | Connecting piece |