1 | Injection nozzle |
2 | Nozzle holder |
3 | Tester |
3.1 | Pressure gauge |
G07.03-3115-11
| Remove | ||
Danger ! | Risk of explosion caused by test oil being ignited. Risk of injury to skin and eyes caused by test oil streaming out | Keep all ignition sources out of the hazard area. Only check injection nozzles in the nozzle testing device. Do not touch the injection nozzle stream. | |
1 | Remove injection nozzle (1) with nozzle holder (2) | ||
2 | Carefully remove all carbonization residues on injection nozzle (1) | ||
3 | Attach injection nozzle (1) with nozzle holder (2) to test equipment (3) | Tester | |
4 | Fill test equipment (3) reservoir with test oil or diesel fuel | Only clean test oil or filtered diesel fuel should be used for testing. | |
| Check | ||
5 | Check leaktightness of injection nozzle (1) | ||
Note test result. | |||
Tester | |||
6 | Check ejection pressure of injection nozzle (1) | ||
Read off ejection pressure at test equipment (3) pressure gauge (3.1) and record result. | |||
Opening pressure of the nozzle holder combination | |||
Pressure difference within the engine | |||
Tester | |||
7 | Check spray pattern and chatter of injection nozzle (1) | ||
Note test result. | |||
Tester | |||
8 | Analyze recorded test result from operation step 5 to 7 | All three test results must meet the respective requirements of the individual operation steps. The injection nozzle (1) must be repaired even if there is just a negative test result: | |
| |||
Disassemble, clean, assemble and set nozzle holder and injection nozzle | |||
| Install | ||
9 | Remove injection nozzle (1) with nozzle holder (2) from test equipment (3) | Tester | |
10 | Install injection nozzle (1) with nozzle holder (2) |
000 589 14 27 00
Tester
Odkazované dokumenty
- ar0703g671201mt
- ar0703g671202mt
- ar0703g671203mt
- ar0703g6713mt
- ar0703g6840mt
- as0703z000101a Nebezpečí výbuchu při vznícení zkušebního oleje. Nebezpečí poranění kůže a očí vytékajícím paprskem zkušebního oleje