AP54.10-T-5430B | Batteries - cleaning, tightening and greasing cable connections. Checking and tightening ground connection | 14.2.12 |
MODEL 613.364 /365
T54.10-0018-01
2 Ground connection
T54.10-0004-01
| Cleaning | ||
Danger! | Risk of explosion caused by escaping oxyhydrogen gas. Risk of injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte (contains diluted sulfuric acid) or metal spatter due to short circuit. Risk of burn injuries caused by short circuit. Risk of poisoning caused by swallowing battery electrolyte (contains diluted sulfuric acid) or absorption of lead over the skin or orifices | No fire, sparks, open flames or smoking. Wear acid-resistant gloves and clothing and safety glasses with side guards. Do not place any conductive objects on the battery and avoid any short circuit from battery positive to ground. Only fill liquid battery electrolyte (diluted sulfuric acid) into suitable and appropriately marked containers. | |
| Notes on battery | All models | |
1 | Clean the terminals (arrows) on the battery posts | ||
|
2 | Grease the terminals, especially the underside of the terminals | Use acid-proof grease, if necessary | |
Disconnect and reconnect the terminals. | |||
| Checking | ||
3 | Check that the terminal screws are firmly tightened, and retighten if necessary | ||
4 | Check that the ground connection (2) of the negative cable is firmly attached to the underbody, and retighten if necessary |
Odkazované dokumenty
- ah5410p000101a Upozornění k akumulátoru
- ah5410p000101a
- as5410z000101a Nebezpečí požáru/exploze kvůli zkratu a unikajícímu výbušnému plynu. Nebezpečí popálení/poranění poleptáním očí, pokožky a sliznic elektrolytem / elektrolytovou mlhou akumulátoru při zkratu nebo následkem světelné