ap5410t5430b

Batteries - cleaning, tightening and greasing cable connections. Checking and tightening ground connection

Typ ap · téma 54.10 · verze 0102 · 2012-02-15

Platí pro: MODEL 613.364 /365

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 2 Podvozek › 54 Elektrické zařízení, výstroj a přístroje › 54.10 Akumulátor, zdroj napětí, měnič napětí — Řada 613 (modely 364, 365)

EinPAS 25 Palubní síť/síť/multifunkční systém › 25.20 Elektrická síť vozidla › 25.20.20 Akumulátor — Řada 613 (modely 364, 365)

AP54.10-T-5430B

Batteries - cleaning, tightening and greasing cable connections. Checking and tightening ground connection

14.2.12

MODEL 613.364 /365

Batteries - cleaning, tightening and greasing cable connections. Checking and   
	tightening ground connection
Batteries - cleaning, tightening and greasing cable connections. Checking and   
	tightening ground connection

T54.10-0018-01

2 Ground connection

T54.10-0004-01

Cleaning

Danger!

Risk of explosion caused by escaping oxyhydrogen gas. Risk of injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte (contains diluted sulfuric acid) or metal spatter due to short circuit. Risk of burn injuries caused by short circuit. Risk of poisoning caused by swallowing battery electrolyte (contains diluted sulfuric acid) or absorption of lead over the skin or orifices

No fire, sparks, open flames or smoking.

Wear acid-resistant gloves and clothing and safety glasses with side guards.

Do not place any conductive objects on the battery and avoid any short circuit from battery positive to ground.

Only fill liquid battery electrolyte (diluted sulfuric acid) into suitable and appropriately marked containers.

AS54.10-Z-0001-01A

Notes on battery

All models

AH54.10-P-0001-01A

1

Clean the terminals (arrows) on the battery posts

2

Grease the terminals, especially the underside of the terminals

Use acid-proof grease, if necessary

Disconnect and reconnect the terminals.
Disconnect the ground cable first, and then the positive cable on the battery. Reconnect in the reverse order. Do not place tools on top of the battery.

Checking

3

Check that the terminal screws are firmly tightened, and retighten if necessary

4

Check that the ground connection (2) of the negative cable is firmly attached to the underbody, and retighten if necessary