AP54.10-T-5430A | Batteries - cleaning, retightening and greasing cable connections. Checking and retightening ground connection | 14.2.12 |
MODEL 613, 671
T54.10-0003-01
1 Terminals
2 Ground connection
T54.10-0004-01
| Cleaning | ||
Danger! | Risk of explosion caused by escaping oxyhydrogen gas. Risk of injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte (contains diluted sulfuric acid) or metal spatter due to short circuit. Risk of burn injuries caused by short circuit. Risk of poisoning caused by swallowing battery electrolyte (contains diluted sulfuric acid) or absorption of lead over the skin or orifices | No fire, sparks, open flames or smoking. Wear acid-resistant gloves and clothing and safety glasses with side guards. Do not place any conductive objects on the battery and avoid any short circuit from battery positive to ground. Only fill liquid battery electrolyte (diluted sulfuric acid) into suitable and appropriately marked containers. | |
| Notes on battery | All models | |
1 | Clean terminals (1) on battery poles | ||
|
2 | Lubricate terminals (1), particularly underneath the terminals | Use acid protection grease, if necessary | |
Detach and attach terminals First disconnect battery ground cable and then positive cable. Connect in the reverse order. Do not put any tools down on the battery | |||
| Checking | ||
3 | Check terminal bolts are seated firmly and re-tighten if necessary | ||
4 | Check negative cable ground connection (2) on underbody is seated firmly and re-tighten if necessary |