ap5410t5430a

Batteries - cleaning, retightening and greasing cable connections. Checking and retightening ground connection

Typ ap · téma 54.10 · verze 0101 · 2012-02-15

Platí pro: MODEL 613, 671

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 2 Podvozek › 54 Elektrické zařízení, výstroj a přístroje › 54.10 Akumulátor, zdroj napětí, měnič napětí — Řada 613 · Řada 671

EinPAS 25 Palubní síť/síť/multifunkční systém › 25.20 Elektrická síť vozidla › 25.20.20 Akumulátor — Řada 613 · Řada 671

AP54.10-T-5430A

Batteries - cleaning, retightening and greasing cable connections. Checking and retightening ground connection

14.2.12

MODEL 613, 671

Batteries - cleaning, retightening and greasing cable connections. Checking and 
	retightening ground connection
Batteries - cleaning, retightening and greasing cable connections. Checking and 
	retightening ground connection

T54.10-0003-01

1 Terminals

2 Ground connection

T54.10-0004-01

Cleaning

Danger!

Risk of explosion caused by escaping oxyhydrogen gas. Risk of injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte (contains diluted sulfuric acid) or metal spatter due to short circuit. Risk of burn injuries caused by short circuit. Risk of poisoning caused by swallowing battery electrolyte (contains diluted sulfuric acid) or absorption of lead over the skin or orifices

No fire, sparks, open flames or smoking.

Wear acid-resistant gloves and clothing and safety glasses with side guards.

Do not place any conductive objects on the battery and avoid any short circuit from battery positive to ground.

Only fill liquid battery electrolyte (diluted sulfuric acid) into suitable and appropriately marked containers.

AS54.10-Z-0001-01A

Notes on battery

All models

AH54.10-P-0001-01A

1

Clean terminals (1) on battery poles

2

Lubricate terminals (1), particularly underneath the terminals

Use acid protection grease, if necessary

Detach and attach terminals

First disconnect battery ground cable and then positive cable. Connect in the reverse order. Do not put any tools down on the battery

Checking

3

Check terminal bolts are seated firmly and re-tighten if necessary

4

Check negative cable ground connection (2) on underbody is seated firmly and re-tighten if necessary

Odkazované dokumenty