ap5410b5430a

Batteries - clean cable connections, re-tighten and grease. Check and re-tightenground connection

Typ ap · téma 54.10 · verze 0101 · 2019-12-17

Platí pro: Model 368 Model 382 Model 384 Model 386 Model 634 Model 688 Model 693 Model 694 Model 695 Model 696 Model 958, 979

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 2 Podvozek › 54 Elektrické zařízení, výstroj a přístroje › 54.10 Akumulátor, zdroj napětí, měnič napětí — Řada 368 · Řada 382 · Řada 384 · Řada 386 · Řada 634 · Řada 688 · Řada 693 · Řada 694 · Řada 695 · Řada 696 · Řada 958 · Řada 979

EinPAS 25 Palubní síť/síť/multifunkční systém › 25.20 Elektrická síť vozidla › 25.20.20 Akumulátor — Řada 368 · Řada 382 · Řada 384 · Řada 386 · Řada 634 · Řada 688 · Řada 693 · Řada 694 · Řada 695 · Řada 696 · Řada 958 · Řada 979

AP54.10-B-5430A

Batteries - clean cable connections, re-tighten and grease. Check and re-tightenground connection

09.12.2019

Model

368

Model

382

Model

384

Model

386

Model

634

Model

688

Model

693

Model

694

Model

695

Model

696

Model

958, 979

Batteries - clean cable connections, re-tighten and grease. Check and           
	re-tightenground connection
Batteries - clean cable connections, re-tighten and grease. Check and           
	re-tightenground connection

1

Connection terminals

T54.10-0003-01

B54.10-0010-01

Danger

Risk of fire/risk of explosion due to short circuit and escaping oxyhydrogen gas. Risk of (burn) injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte/mist, short circuit and arcing. Risk of poisoning caused by swallowing battery electrolyte or absorption of lead through the skin or body orifices. Risk of death due to voltage U >= 30 V AC and U >= 60 V DC.

No fires, sparks, open flames, or smoking. Wear acid-resistant gloves, clothing, and glasses. Pour battery acid only into suitable and appropriately marked containers.

AS54.10-Z-0001-01A

Topical note

Notes on battery

AH54.10-P-0001-01A

1

Remove the plastic protection covers from the batteries

2

Clean the terminals of the battery cables and check whether they are steadily fastened

3

Lubricate battery terminals with industrial vaseline, mainly the lower part of the terminals

If necessary remove the cables.

4

Check the firm attachment of the negative cable to the ground and retighten it

Odkazované dokumenty