AD83.70-P-4003A | Heater booster (ZUH) diagnosis, troubleshooting | 12.8.97 |
MODEL 168 with ENGINE 668.940
with heater booster
MODEL 202 with ENGINE 611.960
with heater booster
MODEL 210 as of 1.9.96 with ENGINE 602.982
with heater booster
MODEL 210 with ENGINE 611.961
with heater booster
Danger! | Risk of explosion due to fuel vapors, risk of poisoning from inhaling combustion gases and risk of injury from burns during or after heater operation. | Do not put stationary heater/auxiliary heater or engine with heater booster into operation in confined spaces or while refuelling. Allow heater unit to cool down after operation and wear safety gloves. | |
Heater booster (ZUH), diagnosis, advanced information | |||
Connect Hand-Held Tester (HHT) and read out fault memory | Models 202, 210 Model 168 | ||
Fault memory | |||
Fault code | Possible cause | Note | Remedy |
No fault code | No fault recognized | If there is a complaint nevertheless: Heater booster (ZUH) diagnosis, troubleshooting | |
| Stationary heater/heater booster control module (A6n1) defective | Replace stationary heater/heater booster unit (A6) | |
| Stationary heater/heater booster control module (A6n1) not/incorrectly coded Variant coding not in order | Check and carry out variant coding | |
| No flame at start of heater boost operation and after automatic repeat start | See HHT | |
| Flame goes out during heater boost operation without a new flame after automatic attempt at starting Flame goes out more than four times during a heater boost cycle | See HHT See HHT | |
Overvoltage Undervoltage | Operating voltage has exceeded 15.5 V for longer than 6 seconds Operating voltage has failed to reach 10.2 V for longer than 20 seconds | ||
|— —|+ — / / —, |— —| – | Circuit of glow pin (A6r2), short-circuit to positive Circuit of glow pin (A6r2), open-circuit or short-circuit to ground | Replace stationary heater/heater booster unit (A6) Replace stationary heater/heater booster unit (A6) | |
| Malfunction lock-out exists: Thermal fuse in stationary heater/heater booster unit (A6) has blown because the coolant in the heater unit has exceeded the maximum permissible temperature of 125°C or 3 different or the same faults have occurred in sequence | See HHT | |
|— —| – — / / —, |— —|+ | Circuit of stationary heater fuel metering pump (Y23), short-circuit to ground Circuit of stationary heater fuel metering pump (Y23), open-circuit or short-circuit to positive | ||
Overload, |— —| — / / — | Combustion air blower (A6m2), overload or short-circuit Combustion air blower (A6m2), open-circuit | See HHT See HHT | |
Overload, |— —| — / / — | Glow pin (A6r2), short-circuit to ground Glow pin (A6r2), open-circuit or short-circuit to positive | See HHT See HHT |
Odkazované dokumenty
- ad0000p200003a
- ad0000p200003c
- ad8370p2002a
- ad8370p5002a
- ad8370p600106a
- ad8370p600107a
- ad8370p600201a
- as8370z000201a Nebezpečí exploze palivových výparů, nebezpečí otravy při vdechnutí spalovacích plynů a nebezpečí poranění v důsledku popálení během nebo po provozu topení