ad0754d3050a

Connect up and run up the liquified gas system. Diagnosis of function check using actual values

Typ ad · téma 07.54 · verze 0100 · 2006-07-25

Platí pro: Engine 111.984 For liquified gas system

Není k dispozici v jazyce „cs“; zobrazeno v jazyce Angličtina.

Zařazení

Funkční skupina 1 Motor › 07 Příprava směsi › 07.54 Systém dodávky plynu a zapalování

Platí také pro motory/převodovky: 111 984

AD07.54-D-3050A

Connect up and run up the liquified gas system. Diagnosis of function check using actual values

3.12.03

Engine 111.984
For liquified gas system

Connect up and run up the liquified gas system. Diagnosis of function check     
	using actual values

D07.54-1126-02

1 Connection cable

2 Socket

3 12 V socket

Installing

Danger!

Risk of accident caused by vehicle starting off by itself when engine is running. Risk of injury caused by contusions and burns when working in engine during starting procedure

Secure vehicle to prevent it from moving.
Wear closed and snug-fitting work clothes.
Do not grasp hot or rotating parts.

AS00.00-Z-0005-01A

1

Push driver's seat forwards

2

Remove cover

3

Connect tester using connecting cable (1) to socket (2) in the seat box

4

Connect tester to 12 V socket (3) (cigarette lighter)

*WH58.30-Z-1054-13A

5

Set selection switch to gas

6

Switch ignition on and start engine

Engine must be at operating temperature.

7

Select program Global data and read the actual values

P1 - P2 = Delta P; this value is important for installation of the evaporator pressure regulator.

AD07.54-D-3050-01A

Commercially available tools

Number

Designation

WH58.30-Z-1054-13A

HHT (for liquified gas system, diagnosis function check via actual values)

Odkazované dokumenty