AD07.54-D-3050-01A | Function check via actual values, diagnosis of liquefied petroleum gas installation |
Function check via actual values using the HHT
Actual value no. | Actual value | Specification |
| Absolute pressure at inlet of gas distributor (press_1) | 1476 mbar |
| Absolute pressure at outlet of gas distributor (press_2) | 350 mbar |
| Absolute pressure in intake pipe | 349 mbar |
| Temperature sensor at outlet of evaporator pressure regulator | 80 °C |
| Gas flow of engine | 0.34 g/s |
| The ratio between the air injection times, calculated by the gasoline control unit and load cycle of the engine | 2.3% |
| Throttle pedal potentiometer signal | 726 MV |
| Engine speed | 760 1 rpm |
| Oxygen sensor signal | 276...1000 mV |
| Signal from fill level sensor at multiple valve for: | |
90 l tank | 150...4500 mV | |
110 l tank | 150...4620 mV | |
| Working cycle of frequency-controlled slide in gas distributor | 20...92 % |
| Number of actuated slides (1 or 2) | 0 |