AD00.19-N-9022EA | Fault code list for parameterizable special module (PSM) control unit | 11.1.08 |
MODEL 374.5 /6, 375.3 /4, 940, 942, 943, 944
MODEL 950.5 /6, 952.5 /6, 953.6, 954.5 with BODY 940.890
MODEL 958.2 /4
Fault code | Fault code description |
0100 | An external control unit for registering temperature in the body or trailer has detected a fault.The information is transmitted via the body CAN bus or trailer CAN bus to control unit PSM Parameterizable Special Module. |
0101 | An external control unit for registering temperature in the body or trailer is not communicating via the body or trailer CAN bus with control unit PSM Parameterizable Special Module. |
0160 | Communication fault on vehicle CAN bus |
0161 | Communication fault with control unit ABS anti-lock braking system or BS Brake control |
0162 | Communication fault with control unit GS Gear control |
0163 | Communication fault with control unit FR drive control |
0164 | Communication fault with control unit INS Instrument |
0200 | An external control unit for registering fluid level in the body or trailer has detected a fault.The information is transmitted via the body CAN bus or trailer CAN bus to control unit PSM Parameterizable Special Module. |
0201 | An external control unit for registering fluid level in the body or trailer is not communicating via the body or trailer CAN bus with control unit PSM Parameterizable Special Module. |
0270 | Single-wire mode of body CAN bus is not possible. |
0271 | Cable CAN-H of body CAN bus faulty |
0272 | Cable CAN-L of body CAN bus faulty |
0300 | An external control unit for registering pressure in the body or trailer has detected a fault.The information is transmitted via the body CAN bus or trailer CAN bus to control unit PSM Parameterizable Special Module. |
0301 | An external control unit for registering pressure in the body or trailer is not communicating via the body or trailer CAN bus with control unit PSM Parameterizable Special Module. |
0370 | Single-wire mode of trailer CAN bus is not possible. |
0371 | Cable CAN-H of trailer CAN bus faulty |
0372 | Cable CAN-L of trailer CAN bus faulty |
0400 | An external control unit for the load ramp approach assist has detected a fault.The information is transmitted via the body CAN bus or trailer CAN bus to control unit PSM Parameterizable Special Module. |
0460 | Communication error on the telematics CAN bus |
1010 | Internal fault in control unit |
1011 | EEPROM error |
1012 | Parameterization fault in control unit |
1013 | Software incompletely loaded. |
1014 | The control unit software is missing or faulty. |
1015 | Checksum error in control unit software |
1016 | A fault has occurred in the control module software. |
1017 | Software: timing error |
1100 | Overvoltage at terminal 30 |
1101 | Undervoltage at terminal 30 |
1102 | Interruption to voltageKl. 30 |
1200 | Overvoltage at terminal 15 |
1201 | Undervoltage at terminal 15 |
1210 | Open circuit in wiring at circuit 15 |
2020 | Output of 'Engine running, generator OK' (pin X4 18/9) has Short circuit to ground. |
2021 | Output of 'Engine running, generator OK' (pin X4 18/9) has Short circuit to positive or Open circuit. |
2120 | Output of 'Switching off retarder' (pin X4 18/10) has Short circuit to ground. |
2121 | Output of 'Switching off retarder' (pin X4 18/10) has Short circuit to positive or Open circuit. |
2220 | Output of 'Actuation of clutch locking cylinder' (pin X4 18/11) has Short circuit to ground. |
2221 | Output of 'Actuation of clutch locking cylinder' (pin X4 18/11) has Short circuit to positive or Open circuit. |
2320 | Output of 'Actuation of clutch operating valve' (pin X4 18/12) has Short circuit to ground. |
2321 | Output of 'Actuation of clutch operating valve' (pin X4 18/12) has Short circuit to positive or Open circuit. |
2420 | 'Output' actuation (pin X4 18/13) has Short circuit to ground. |
2421 | 'Output' actuation (pin X4 18/13) has Short circuit to positive or Open circuit. |
2520 | Output of 'PTO feedback' (pin X4 18/14) has Short circuit to ground. |
2521 | Output of 'PTO feedback' (pin X4 18/14) has Short circuit to positive or Open circuit. |
2620 | Output of 'Neutral position' (pin X4 18/15) has Short circuit to ground. |
2621 | Output of 'Neutral position' (pin X4 18/15) has Short circuit to positive or Open circuit. |
2720 | Output of 'Actuation of PTO 1' (pin X4 18/16) has Short circuit to ground. |
2721 | Output of 'Actuation of PTO 1' (pin X4 18/16) has Short circuit to positive or Open circuit. |
2722 | Not feedback of PTO 1 (pin X3 15/7) despite actuation of PTO 1 (pin X4 18/16) |
2723 | No actuation of PTO 1 (pin X4 18/16) despite feedback PTO 1 (pin X3 15/7) |
2820 | Output of 'Actuation of PTO 2' (pin X4 18/17) has Short circuit to ground. |
2821 | Output of 'Actuation of PTO 2' (pin X4 18/17) has Short circuit to positive or Open circuit. |
2822 | Not feedback of PTO 2 (pin X3 15/8) despite actuation of PTO 2 (pin X4 18/17) |
2823 | No actuation of PTO 2 (pin X4 18/17) despite feedback PTO 2 (pin X3 15/8) |
2920 | Output of 'Actuation of PTO 3' (pin X4 18/18,) has Short circuit to ground. |
2921 | Output of 'Actuation of PTO 3' (pin X4 18/18) has Short circuit to positive or Open circuit. |
2922 | Not feedback of PTO 3 (pin X3 15/9) despite actuation of PTO 2 (pin X4 18/18) |
2923 | No actuation of PTO 3 (pin X4 18/18) despite feedback PTO 3 (pin X3 15/9) |
3020 | Output of 'Reverse gear engaged' (pin X4 18/9) has Short circuit to ground. |
3021 | Output of 'Reverse gear engaged' (pin X4 18/9) has Short circuit to positive or Open circuit. |
3120 | Output of 'Gear 1 engaged' (pin X4 18/10) has Short circuit to ground. |
3121 | Output of 'Gear 1 engaged' (pin X4 18/10) has Short circuit to positive or Open circuit. |
3220 | Output of 'Kickdown' (pin X4 18/11) has Short circuit to ground. |
3221 | Output of 'Kickdown' (pin X4 18/11) has Short circuit to positive or Open circuit. |
3320 | Output of 'Frequent stop brake' (pin X4 18/12) has Short circuit to ground. |
3321 | Output of 'Frequent stop brake' (pin X4 18/12) has Short circuit to positive or Open circuit. |
3420 | Output of 'ABS fault' (pin X4 18/13) has Short circuit to ground. |
3421 | Output of 'ABS fault' (pin X4 18/13) has Short circuit to positive or Open circuit. |
3520 | Output of 'Gear 2 engaged' (pin X4 18/14) has Short circuit to ground. |
3521 | Output of 'Gear 2 engaged' (pin X4 18/14) has Short circuit to positive or Open circuit. |
4020 | Output X4 18/9 has Short circuit to ground. |
4021 | Output X4 18/9 has Short circuit to positive or Open circuit. |
4120 | Output X4 18/10 has Short circuit to ground. |
4121 | Output X4 18/10 has Short circuit to positive or Open circuit. |
4220 | Output X4 18/11 has Short circuit to ground. |
4221 | Output X4 18/11 has Short circuit to positive or Open circuit. |
4320 | Output X4 18/12 has Short circuit to ground. |
4321 | Output X4 18/12 has Short circuit to positive or Open circuit. |
4420 | Output X4 18/13 has Short circuit to ground. |
4421 | Output X4 18/13 has Short circuit to positive or Open circuit. |
4520 | Output X4 18/14 has Short circuit to ground. |
4521 | Output X4 18/14 has Short circuit to positive or Open circuit. |
4620 | Output X4 18/15 has Short circuit to ground. |
4621 | Output X4 18/15 has Short circuit to positive or Open circuit. |
4720 | Output X4 18/16 has Short circuit to ground. |
4721 | Output X4 18/16 has Short circuit to positive or Open circuit. |
4820 | Output X4 18/17 has Short circuit to ground. |
4821 | Output X4 18/17 has Short circuit to positive or Open circuit. |
4920 | Output X4 18/18 has Short circuit to ground. |
4921 | Output X4 18/18 has Short circuit to positive or Open circuit. |
5020 | Output of 'Engine speed signal' (pin X1 18/4) has Short circuit to ground. |
5021 | Output of 'Engine speed signal' (pin X1 18/4) has Short circuit to positive or Open circuit. |
5120 | Output of 'Vehicle speed signal' (pin X1 18/5) has Short circuit to ground. |
5121 | Output of 'Vehicle speed signal' (pin X1 18/5) has Short circuit to positive or Open circuit. |
5220 | Output of 'Torque specified value signal' (pin X1 18/6) has Short circuit to ground. |
5221 | Output of 'Torque specified value signal' (pin X1 18/6) has Short circuit to positive or Open circuit. |
5320 | Output of 'Limit load signal' (pin X1 18/7) has Short circuit to ground. |
5321 | Output of 'Limit load signal' (pin X1 18/7) has Short circuit to positive or Short circuit. |
5420 | 'PWM1 signal' output (pin X1 18/8) has Short circuit to ground. |
5421 | 'PWM1 signal' output (pin X1 18/8) has Short circuit to positive or Open circuit. |
5520 | 'PWM2 signal' output (pin X1 18/9) has Short circuit to ground. |
5521 | 'PWM2 signal' output (pin X1 18/9) has Short circuit to positive or Open circuit. |
6040 | Input signal of manual throttle actuator (pin X1 18/11) has Short circuit to ground or Open circuit. |
6041 | Input signal of manual throttle actuator (pin X1 18/11) has Short circuit to positive. |
6042 | Supply cable of manual throttle actuator (pin X1 18/10) has Short circuit to ground. |
6043 | Supply cable of manual throttle actuator (pin X1 18/10) has Short circuit to positive. |
6140 | Input of 'Engine start' (pin X2 18/7) has Short circuit to ground. |
6141 | Input of 'Engine start' (pin X2 18/7) has Short circuit to positive. |
6240 | Input of 'Engine stop' (pin X2 18/8) has Short circuit to ground. |
6241 | Input of 'Engine stop' (pin X2 18/8) has Short circuit to positive. |
6340 | Input of 'Start lockout' (pin X2 18/9) has Short circuit to ground. |
6341 | Input of 'Start lockout' (pin X2 18/9) has Short circuit to positive. |
6440 | Input of 'Step plate switch' (pin X2 18/13) has Short circuit to ground. |
6441 | Input of 'Step plate switch' (pin X2 18/13) has Short circuit to positive. |
6540 | Input of 'Clutch remote control' (pin X4 18/4) has Short circuit to ground. |
6541 | Input of 'Clutch remote control' (pin X4 18/4) has Short circuit to positive. |
6640 | Input of 'ABS control' (pin X4 18/4) has Short circuit to ground. |
6641 | Input of 'ABS control' (pin X4 18/4) has Short circuit to positive. |
6740 | Input of 'Reverse gear interrogation' (pin X4 18/4) has Short circuit to ground. |
6741 | Input of 'Reverse gear interrogation' (pin X4 18/4) has Short circuit to positive. |
6840 | Input of 'Shift gear into neutral position' (pin X4 18/4) has Short circuit to ground. |
6841 | Input of 'Shift gear into neutral position' (pin X4 18/4) has Short circuit to positive. |
6940 | Input of 'Retarder status' (pin X4 18/5) has Short circuit to ground. |
6941 | Input of 'Retarder status' (pin X4 18/5) has Short circuit to positive. |
7040 | Input of 'Parking brake' (pin X4 18/5) has Short circuit to ground. |
7041 | Input of 'Parking brake' (pin X4 18/5) has Short circuit to positive. |
7440 | Digital input X2 18/7 has Short circuit to ground. |
7441 | Digital input X2 18/7 has Short circuit to positive. |
7540 | Digital input X2 18/8 has Short circuit to ground. |
7541 | Digital input X2 18/8 has Short circuit to positive. |
7640 | Digital input X2 18/9 has Short circuit to ground. |
7641 | Digital input X2 18/9 has Short circuit to positive. |
7740 | Digital input X2 18/13 has Short circuit to ground. |
7741 | Digital input X2 18/13 has Short circuit to positive. |
7840 | Digital input X4 18/4 has Short circuit to ground. |
7841 | Digital input X4 18/4 has Short circuit to positive. |
7940 | Digital input X4 18/5 has Short circuit to ground. |
7941 | Digital input X4 18/5 has Short circuit to positive. |
8080 | Protect function for PTOs has been bridged manually. |