ar8370w5758a

Removing and installing glow plug

Loại ar · chủ đề 83.70 · phiên bản 0101 · 2004-09-17

Áp dụng cho: MODEL 950, 952, 953, 954 with BODY 940.899 with CODE (H62) Warm air heater "Eberspächer D3 LP" MODEL 950, 952, 953, 954 with BODY 942.899 with CODE (H62) Warm air heater "Eberspächer D3 LP" MODEL 970, 972, 974, 975, 976 with BODY 972.899 with CODE (H62) Warm air auxiliary heater "Eberspächer" D3 LP'

Không có bằng “vi”; đang hiển thị bằng tiếng Anh.

Vị trí

Nhóm chức năng 3 Body › 83 Climate control › 83.70 Auxiliary/supplementary heater — Dòng 940 (mẫu 899) · Dòng 942 (mẫu 899) · Dòng 950 · Dòng 952 · Dòng 953 · Dòng 954 · Dòng 970 · Dòng 972 · Dòng 974 · Dòng 975 · Dòng 976

EinPAS 39 Heating/ventilation/cooling › 39.25 Stationary heater/auxiliary heater › 39.25.30 Heater — Dòng 940 (mẫu 899) · Dòng 942 (mẫu 899) · Dòng 950 · Dòng 952 · Dòng 953 · Dòng 954 · Dòng 970 · Dòng 972 · Dòng 974 · Dòng 975 · Dòng 976

AR83.70-W-5758A

Removing and installing glow plug

2.2.98

MODEL 950, 952, 953, 954 with BODY 940.899 with CODE (H62) Warm air heater "Eberspächer D3 LP"

MODEL 950, 952, 953, 954 with BODY 942.899 with CODE (H62) Warm air heater "Eberspächer D3 LP"

MODEL 970, 972, 974, 975, 976 with BODY 972.899 with CODE (H62) Warm air auxiliary heater "Eberspächer" D3 LP

Removing and installing glow plug

W83.70-0048-06

1 Hex. screw
2 Cover
3 Glow plug
4 Gasket
5 Glow plug screen

Removal, installation

1

Disconnect ground lead from battery

Do not interrupt main battery supply while heater is in operation or during heater shut-off delay.

2

Remove cover (2)

3

Unscrew connection cable from glow plug

4

Remove glow plug (3)

Installation: Replace gasket (4).

5

Remove glow plug screen (5)

Installation: Observe position of lug (arrow A) on glow plug screen. The hole (arrow B) for glow plug ventilation must be free.

6

Reinstall in opposite order

Danger!

Fuel vapors present an explosion hazard. Combustion gases are toxic when inhaled. Heater can cause severe burns during and after operation.

Do not start up or operate stationary heaters, auxiliary heaters or engines with heater boosters in closed rooms or in the vicinity of service stations. Allow heater to cool off after operation and wear protective gloves.

AS83.70-Z-0002-01A

7

Check stationary heater for proper function

AR83.70-W-5302-02C

Tài liệu được tham chiếu