AR43.40-W-1005PR | Enable permanent magnet retarder | 31.1.12 |
MODEL 970.0 /2 with TRANSMISSION 712.62 /63, 715.050 /060 with BODY 972.890
except CODE (B95) No antilock brake system
except CODE (MK3) Variable vehicle speed limit 30 km/h and backup shift lock for refuse vehicles
not in combination with transmission-driven power takeoff
MODEL 974.2 with TRANSMISSION 712.63, 715.060 with BODY 972.890
except CODE (B95) No antilock brake system
except CODE (MK3) Variable vehicle speed limit 30 km/h and backup shift lock for refuse vehicles
not in combination with transmission-driven power takeoff
Danger! | Risk of death caused by working on permanent magnet retarder for groups of persons with implants. Risk of injury caused by burns that may occur due to contact with the hot rotor. | For persons with implants, a minimum distance of 30 cm between the permanent magnet retarder and the body parts of the affected person is to be maintained as a safe distance from the permanent magnet retarder. Do not touch hot or rotating parts. | |
1 | Connect Star Diagnosis | ||
2 | Switch on ignition | ||
3 | Start "XENTRY" application | ||
4 | Select "Mercedes-Benz" brand | ||
5 | Select "Truck" | ||
6 | Select "Automatic vehicle definition" menu | ||
7 | Start "XENTRY Diagnostics" application | ||
8 | Select Short test | ||
9 | Select "INS Instrument" menu | ||
10 | Select "Control unit adaptations" | ||
11 | Select "Parameterization" | ||
12 | Select "Parameter 01 - 24" | ||
13 | Select parameter 07 "RS retarder control" | ||
14 | Set parameter 07 "RS retarder control" to "PRESENT" and "NOT DIAGNOSIS CAPABLE" | ||
15 | Select "PSM parameterizable special module" system | ||
16 | Select "Control unit adaptations" | ||
17 | Select "Parameterization" | ||
18 | Make backup copy of "PSM parameterizable special module" parameterization | ||
19 | Select "General parameter set" | ||
20 | Select equation 300 "Retarder shutoff" | ||
21 | Select "All parameters" | ||
22 | Select parameter "300.10 ABS intervention (Pin X4 18/4 ... Pin X4 18/7)" | ||
23 | Set parameter "300.10 ABS intervention (Pin X4 18/4 ... Pin X4 18/7)" to "NO" | ||
24 | Select parameter "300.20 ABS intervention" | ||
25 | Set parameter "300.20 ABS intervention" to "YES" | ||
26 | Select parameter "300.500 Retarder switch off (Pin X4 18/10)" | ||
27 | Select parameter "300.500 Retarder switch off (Pin X4 18/10)" to "YES" | ||
28 | Select equation 310 "Retarder status" | ||
29 | Select "All parameters" | ||
30 | Select parameter "310.10 Retarder state (Pin X4 18/5 ... Pin X4 18/8)" | ||
31 | Select parameter "310.10 Retarder state (Pin X4 18/5 ... Pin X4 18/8)" to "YES" | ||
32 | Select equation 400 "Assignment of FCAN events for gearshift output" | ||
33 | Select parameter 02 "Assignment of FCAN bus event for output (Pin X4 18/9)" | ||
34 | Select parameter 400.10 "Designation (Pin X4 18/9)" | ||
35 | Set service brake to "ACTIVE" | ||
36 | Select parameter 400.50 "Activation of output (Pin X4 18/9)" | ||
37 | Set "Activation of output (Pin X4 18/9)" to "YES" | ||
38 | Select parameter 03 "Assignment of FCAN bus event for output (Pin X4 18/10)" | ||
39 | Select parameter 400.60 "Designation (Pin X4 18/10)" | ||
40 | Set "Designation (Pin X4 18/10)" to "ABS intervention ACTIVE" | ||
41 | Select parameter 400.100 "Activation of output (Pin X4 18/10)" | ||
42 | Set "Activation of output (Pin X4 18/10)" to "YES" | ||
43 | Select "FR drive control" system | ||
44 | Select "Control unit adaptations" | ||
45 | Select "Teach-in processes". | ||
46 | Select "CAN environment" | ||
47 | End "XENTRY" application | ||
48 | Switch off ignition | ||
49 | Disconnect Star Diagnosis |