ar1440b2032a

Remove/install check valve at air controller unit of exhaust aftertreatment system

Tür ar · konu 14.40 · sürüm 0301 · 2019-11-19

Geçerli olduğu: Engine 924.9 in model 368, 384.0/2, 685.282/284/289/290, 979.2 Engine 926.9 in model 368, 382.17/18, 384.0

“tr” dilinde mevcut değil; İngilizce gösteriliyor.

Konumu

Fonksiyon grubu 1 Motor › 14 Egzoz manifoldu, Motor freni, Egzoz gazı temizleme tertibatı › 14.40 Egzos gazı ilave temizleme işlemi, AdBlue — Seri 368 · Seri 382 (modeller 17*, 18*) · Seri 384 (modeller 0**, 2**) · Seri 685 (modeller 282, 284, 289, 290) · Seri 979 (modeller 2**)

EinPAS 15 Motor › 15.40 Egzoz sistemi/egzoz emisyon iyileştirme sistemi › 15.40.13 Hat/hortum/ventil — Seri 368 · Seri 382 (modeller 17*, 18*) · Seri 384 (modeller 0**, 2**) · Seri 685 (modeller 282, 284, 289, 290) · Seri 979 (modeller 2**)

Motorlar/şanzımanlar için de geçerli: 924 9**, 926 9**

AR14.40-B-2032A

Remove/install check valve at air controller unit of exhaust aftertreatment system

31.10.2019

Engine

924.9 in model 368, 384.0/2, 685.282/284/289/290, 979.2

Engine

926.9 in model 368, 382.17/18, 384.0

Remove/install check valve at air controller unit of exhaust aftertreatment     
	system

Represented in vehicle 382.177

1

Compressed air inlet

2

Compressed air outlet

3

Connection bolt

4

Connection bolt

5

Check valve (8.01)

6

Pressure regulating valve (33.03)

B14.40-0075-11

Remove/install

1

Remove the pressure regulating valve (33.03) (6)

Remove/install pressure limiting valve at air controller unit of the exhaust aftertreatment system
.

AR14.40-B-2016A

Topical note

Notes on self-locking nuts and bolts

AH00.00-N-0001-01A

Notes on compressed air connection systems

AH00.18-N-0001-01A

2

Loosen the connection bolt (4) from the compressed air inlet (1)

After shutting the engine down, the compressed air continues to flow through some compressed air lines for approximately 3 min. For this reason, start working on the compressed air control unit, after this time has elapsed.

Firstly, slacken the connection screw (4) in two turns to release the pressure of the system and then remove it completely.

.Compressed air connection system "VOSS 232"

*BA00.18-B-1002-01A

3

Loosen the connection bolt (3) from the compressed air outlet (2)

Firstly, slacken the connection bolt (3) by two turns to let the pressure out of the system, then remove it completely.

.Compressed air connection system "VOSS 232"

*BA00.18-B-1002-01A

4

Remove the check valve (8.01) (5)

5

Installation in reverse order

6

Charge the compressed air system up to the limiting pressure

Compressed air piping

Number

Designation

Model all (BUS, TRUCK)

BA00.18-B-1002-01A

Compressed air connection system "VOSS 232"

M16

Nm

14

M14

Nm

14

M22

Nm

14

Atıfta bulunulan belgeler