W14.40-1184-08
1 | Metering unit | 3 | Electrical connector | ||||
2 | O-Ring | B128 | SCR compressed air pressure sensor |
Warning | Risk of burn injuries and scalding when working at AdBlue lines and the components attached to them. Risk of injury to skin and eyes when handling AdBlue. Risk of poisoning caused by swallowing AdBlue | Pour AdBlue into suitable containers only. Wait until the pressure is released before starting any work on the exhaust aftertreatment system. | |
Notes on use, material properties and handling of AdBlue® | . | ||
| Remove/install | ||
Warning | Risk of injury caused by body parts being pinched or crushed as cab is tilted | Ensure that no one is within the tilting range of the cab as it is being tilted. Always tilt the cab all the way to the end position and secure with the safety strut. | |
1 | Turn off ignition | ||
2 | Tilt the cabin | ||
Topical note | Notes on tilting the cab | . | |
3 | Detach the electric connector (3) in the SCR compressed air pressure sensor (B128) | ||
4 | Remove the pressure sensor from the SCR compressed air (128) | AdBlue compressed air pressure sensor SCR on dosage unit | |
5 | Install on the reverse order |
Atıfta bulunulan belgeler
- ah1440n000101a AdBlue uygulaması, madde özellikleri ve kullanımı ile ilgili hatırlatmalar
- ah6080n000301a Sürücü kabininin devrilmesine yönelik hatırlatmalar
- as1440z000101a AdBlue hatlarında ve bu hatlara bağlı yapı parçaları ile çalışırken yanma ve haşlanma tehlikesi. AdBlue ile çalışırken deri ve gözlerde yaralanma tehlikesi. AdBlue'nin içilmesine bağlı zehirlenme tehlikesi
- as6080z000101a Sürücü kabininin devrilmesi sırasında sıkışma veya ezilme nedeniyle yaralanma tehlikesi