N09.10-2049-05
1 Air cleaner housing
2 Cap
3 Air cleaner cartridge
4 Charge air hose
5 Hydraulic lines
| Remove/install | ||
1 | Turn cap (2) to the left into "open" direction | Installation: Insert cap (2) into the air cleaner housing (1) and turn as far as the stop in "close" direction. | |
2 | Remove air cleaner element (3) from air cleaner housing (1), push charge air hose (4) and hydraulic lines (5) to the side for this step | Vacuum out air cleaner housing (1), to the extent necessary and possible, or wipe out with a moist cloth. Installation: Ensure the air cleaner element (3) is properly seated on the sealing surfaces. | |
3 | Install in the reverse order | ||
4 | Confirm replacement of the air cleaner element in the maintenance booklet |