SI82.20-P-0003A | Service information: Coding parameter set for interior protection when replacing the overhead control panel control unit | 8.2.10 |
MODEL 204, 207.3, 212 with CODE (882) Interior monitoring (with ATA [EDW] only)
Due to recent events we would point out that the parameter set of interior protection must be coded when replacing the overhead control panel control unit
This is due to the fact that the interior protection and tow-away protection control unit is permanently connected with the overhead control panel control unit and is therefore also replaced.
The coding of the body variant is to be carried out in the control unit view with Xentry DAS:
Menu: "Body"-"SAM-H"-"Interior protection LIN"-"Adaptations"-"Configuration"-"Manual adjustments"-" Commissioning of interior protection and tow-away protection control unit" .