si4220l0001a

Parking brake service information

ประเภท si · หัวข้อ 42.20 · เวอร์ชัน 0101 · 2003-06-18

ใช้กับ: MODELS 668.###, 670.### 1N up to 080120 with CODE (B65) heated air drier (single-chamber system) with power-assisted service brake with electrical air compressor for parking brake system (FBA)

ไม่มีใน “th” แสดงเป็น อังกฤษ

ตำแหน่ง

กลุ่มฟังก์ชัน 2 Chassis › 42 Brakes - hydraulic and mechanical systems › 42.20 Parking brake — ซีรีส์ 668 · ซีรีส์ 670

EinPAS 21 Brakes/vacuum system/compressed-air system › 21.16 Parking brake › 21.16.5 Parking brake, complete — ซีรีส์ 668 · ซีรีส์ 670

EinPAS 45 Data/information › 45.20 Information/measures › 45.20.20 Service information — ซีรีส์ 668 · ซีรีส์ 670

SI42.20-L-0001A

Parking brake service information

28.2.00

MODELS 668.###, 670.### 1N up to 080120 with CODE (B65) heated air drier (single-chamber system)
with power-assisted service brake with electrical air compressor for parking brake system (FBA)

Modification notes

28.2.00

Replaces STIN 43.04L005 of 24.2.00

New K27 relay when retrofitting heated air dryer.

K27 relay with overrunning diode is not compatible!

Please read installation instructions before fitting.

Cost procedure:
when retrofitting heated air dryer (code B65).

Use of relay K27 with overrunning diode:

Before using relay K27 the wires in compartments 2 (21.00 br/bl) must be replaced with the wires in compartment 4 (21.00 bl) in the 5-pin relay pedestal.

After installing the relay, do not forget to attach a sticker containing the installation data on the inside of the e-compartment cover (to do this, print document, cut out figure 2 and complete).

Parking brake service information
Parking brake service information

L42.20-0047-01

Before replacing.

A term. 85

B term. 86

After replacing.

A term. 86

B term. 85

Connections switched and new relay with erase diode installed on:.................................

L42.20-0057-01

Parts ordering notes

Part no.

Designation

Quantity

A 000 835 01 59

12 V relay

as required

A 003 545 98 05

24 V relay

as required