PE83.30-T-2000-60IB | Legend of wiring diagram for air conditioning system | MODEL NMB671.015 /020 /021 /030 /042 |
Code | Designation | Coordinates |
A1 | Battery compartment | 4D |
A1f1 | Air conditioning fuse | 10C |
A1f2 | Main fuse 80A | 5C |
A107 | Air conditioning electrical control panel | 12E |
A107f1 | Fuse - blower motor 1, evaporator | 18G |
A107f2 | Fuse - blower motor 2, evaporator | 23G |
A107f3 | Fuse - blower motor 3, evaporator | 34G |
A107f4 | Fuse - blower motor 4, evaporator | 40G |
A107f5 | Fuse - blower motor 5, evaporator | 31G |
A107f6 | Fuse - blower motor 6, evaporator | 45G |
A107f15 | Fuse - evaporator blower, speed 2 | 26D |
A107f16 | Fuse - evaporator blower, speed 1 | 13D |
G2 | Battery (2x12V) | 6H |
G3 | Alternator 2 | 3L |
K1/0 | Relay - evaporator blower, speed 1 | 14E |
K1/1 | Relay - evaporator blower, speed 1 | 17E |
K1/2 | Relay - evaporator blower, speed 1 | 33E |
K1/3 | Relay - evaporator blower, speed 1 | 30E |
K2-0 | Relay - evaporator blower, speed 2 | 27E |
K2-1 | Relay - evaporator blower, speed 2 | 20E |
K2-2 | Relay - evaporator blower, speed 2 | 23E |
K2-3 | Relay - evaporator blower, speed 2 | 36E |
K2-4 | Relay - evaporator blower, speed 2 | 39E |
K2-5 | Relay - evaporator blower, speed 2 | 42E |
K2-6 | Relay - evaporator blower, speed 2 | 44E |
K3 | Main battery switch relay | 9L |
M1/11 | Blower motor 1, evaporator (left) | 18L |
M1/12 | Blower motor 2, evaporator (right) | 24L |
M1/13 | Blower motor 3, evaporator (left) | 35L |
M1/14 | Blower motor 4, evaporator (right) | 40L |
M1/15 | Blower motor 5, evaporator (left) | 32L |
M1/16 | Blower motor 6, evaporator (right) | 46L |
Q1 | Battery cutoff relay | 6D |
S1/2 | Fan switch, speed 1 and 2 | 16L |
W4/2 | Battery compartment ground | 6L |
W6/1 | Ground (electronics compartment) | 7F |
X2x16 | Electronics compartment connector | 8F |
X2x30 | Electrical compartment terminal points | 4H |
X2x32 | Air conditioning terminal point | 12C |
XST1 | Air conditioning connector | 15G |