"Controlled heater operation", function

23.9.96

MODEL 950, 952, 953, 954 with CODE (H61) Hot air auxiliary heater "Webasto" Air Top 2000

"Controlled heater operation", function

W83.70-0109-06

1 Heater
2 Hot air intake
3 Combustion and hot air blower
4 Control circuit board
5 Flame monitor
6 Glow pin
7 Burner insert
8 Temperature limiter
9 Combustion tube
10 Heat exchanger
11 Fuel metering pump
12 Timer
13 Rotary potentiometer

HE Hot air inlet
HA Hot air outlet
V Combustion air
A Exhaust

Function sequence "controlled heating"

Controlled operation

The heater (1) is switched on with the timer (12).

The heater has completed the start-up phase and is now in the controlled operation phase. It continues at maximum output until the air sucked in has reached the set cab temperature. Then the heating capacity is reduced. The control circuit board (4) decreases the speed of the combustion and hot air blower (3) to 60 % of the maximum speed and proportionally decreases the cycling frequency for the fuel metering pump (11) until the set cab temperature is exceeded.

If the temperature set on the timer is exceeded and the minimum heating capacity has been reached for more than
5 seconds, the control circuit board switches off the fuel metering pump discontinuing combustion.

The combustion and hot air blower continues to run for
155 seconds at 60 % of the maximum speed to cool down and purge the heater (cooling phase with shut-off delay).

Controlled shut-off phase

The heater has completed the cooling phase with delay shut-off and is now in the controlled shut-off phase.

The combustion and hot air blower continues to run at minimum speed blowing air out of the cab across the temperature sensor on the control circuit board.

When the temperature drops below the setting on the timer the heater is started up without the break-loose phase. The heater starts running again.

Heat exchanger, location/purpose/design

GF83.70-W-4017B

Glow pin, location/purpose/design

GF83.70-W-4020B

Flame monitor, location/purpose/design

GF83.70-W-4021B

Timer, location/purpose/design

GF83.70-W-4022B

Fuel metering pump, location/purpose/design

GF83.70-W-4023A

Temperature limiter, location/purpose/design

GF83.70-W-4026A

Combustion and hot air blower, location/purpose/design

GF83.70-W-4027A

Auxiliary heater control circuit board, location/purpose/design

GF83.70-W-4028A

Burner insert with combustion tube, location/purpose/design

GF83.70-W-4029A